• Features

    • SIL3 and PLe certification
    • Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
    • 2 encoder inputs with format SIN+, SIN-, COS+, COS- [1 Vss]
    • 2 pulse inputs with format A, /A, B, /B [RS422]
    • 2 pulse- or control inputs with format A, B, 90° [HTL / PNP] (for rotary encoder, proximity switches or commands)
    • Input frequency up to 500 kHz
    • Forced-guided redundant output relay (NO)
    • 4 control outputs with push-pull characteristic, short-circuit-proof, [HTL], each inverse and redundant
    • Safety related 14 bit analog output for 4 ... 20 mA (scalable)
    • With signal splitter
    • Power supply 18 ... 30 V
    • Compact housing for 35 mm mounting top hat rail
    • (according to EN 60715)
    • Setup via USB port by operator software or plug-in display and programming unit BG230 (accessories)
  • Features

    • SIL3 and PLe certification
    • Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
    • 2 encoder inputs with format SIN+, SIN-, COS+, COS- [1 Vss]
    • 2 pulse inputs with format A, /A, B, /B [RS422]
    • 2 pulse- or control inputs with format A, B, 90° [HTL / PNP] (for rotary encoder, proximity switches or commands)
    • Input frequency up to 500 kHz
    • Forced-guided redundant output relay (NO)
    • 4 control outputs with push-pull characteristics, short-circuit-proof, [HTL], each inverse and redundant
    • Safety-related 14-bit analogue output for 4 ... 20 mA (scalable)
    • Power supply 18 ... 30 V
    • Compact housing for 35 mm mounting top-hat rail (according to EN 60715)
    • Setup via USB port by operator software or plug-in display and programming unit BG230 (accessories)
  • Features

    • SIL3 and PLe certification
    • Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
    • 2 encoder input with format SIN+, SIN-, COS+, COS- [1 Vss]
    • 2 pulse- or control inputs with format A, B, 90° [HTL / PNP] (for rotary encoder, proximity switches or commands)
    • Input frequency up to 500 kHz
    • Forced-guided redundant output relay (NO)
    • 4 control outputs with push-pull characteristic, short-circuit-proof, [HTL], each inverse and redundant
    • Safety-related 14 bit analogue output for 4 ... 20 mA (scalable)
    • With signal splitter
    • Power supply 18 ... 30 V
    • Compact housing for 35 mm mounting top hat rail (according to EN 60715)
    • Setup via USB port by operator software or plug-in display and programming unit BG230 (accessories)
  • Features

    • SIL3 and PLe certification
    • Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
    • 2 encoder input with format SIN+, SIN-, COS+, COS- [1 Vss]
    • 2 pulse inputs with format A, /A, B, /B [RS422]
    • 2 pulse- or control inputs with format A, B, 90° [HTL / PNP] (for rotary encoder, proximity switches or commands)
    • Input frequency up to 500 kHz
    • Forced-guided redundant output relay (NO)
    • 4 control outputs with push-pull characteristic, short-circuit-proof, [HTL], each inverse and redundant
    • Safety related 14 bit analog output for 4 ... 20 mA (scalable)
    • Power supply 18 ... 30 V
    • Compact housing for 35 mm mounting top hat rail (according to EN 60715)
    • Setup via USB port by operator software or plug-in display and programming unit BG230 (accessories)
  • Features

    • SIL3 and PLe certification
    • Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
    • 2 incremental encoder inputs with format A, /A, B, /B, Z, /Z [HTL differencial, HTL single ended, RS422]
    • 8 control inputs [HTL / PNP]
    • Input frequency up to 500 kHz
    • 2 relay outputs 5... 250 VAC / VDC (NO)
    • 4 x 2 control outputs with push-pull characteristic, short-circuit-proof, [HTL], antivalent or equivalent redundant or simply used
    • Safety related 14 bit analog output for 4 ... 20 mA (scalable)
    • Signal splitter
    • Power supply 18 ... 30 V
    • Wire monitoring of the sensor signals
    • Compact housing for 35 mm mounting top hat rail (according to EN 60715)
    • USB interface in combination with the user interface OS6.0 for the parameterization of the safety speed monitor
    • BG200 operator panel for easy parameterization and display (optional)
  • Features

    • SIL3 and PLe certification (depends on the used encoder/sensor arrangement)
    • Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
    • 1 incremental encoder input with format A, /A, B, /B, Z, /Z [HTL differencial, RS422]
    • 8 control inputs [HTL / PNP]
    • Input frequency up to 500 kHz
    • 2 relay outputs 5... 250 VAC / VDC (NO)
    • 4 x 2 control outputs with push-pull characteristic, short-circuit-proof, [HTL], antivalent or equivalent redundant or simply used
    • Safety related 14 bit analog output for 4 ... 20 mA (scalable)
    • Signal splitter
    • Power supply 18 ... 30 V
    • Wire monitoring of the sensor signals
    • Compact housing for 35 mm mounting top hat rail (according to EN 60715)
    • USB interface in combination with the user interface OS6.0 for the parameterization of the safety speed monitor
    • BG200 operator panel for easy parameterization and display (optional)
  • Features

    • Single channel pulse input [HTL]
    • Input frequency up to 20 kHz
    • Programmable input filter for mechanical input contacts
    • Power supply 24 VDC
    • Miniature norm panel housing
    • 6 digits LED display with 8 mm height
    • Display range  -199999 ... 999999
    • Dimension B x H x T = 48 x 24 x 59 mm (1.89 x 0.94 x 2.32 ")
  • Features

    • Pulse input with format A, B, 90° [HTL], single channel as an option
    • HTL inputs for encoder and sensors with NPN / PNP or NAMUR switching characteristics
    • Input frequency up to 250 kHz
    • 3 control inputs for HTL / PNP signals
    • Power supply 18 ... 30 VDC
    • 24 V auxiliary output for encoder supply
    • 3.78 x 1.89-inch norm panel housing and IP65 protection
    • Bright and high-contrast display with event-dependent color variations
    • Emulation of a 7-segment display inclusively icons and units
    • Intuitive and easy parameterization by plain text and touchscreen
    • Multi-functional device for speed, position, timer, counter or velocity application
    • Operating modes such as scaling, average filter, start-up suppression
    • Linearization with 24 control points

    Options

    • Option AC: Power supply 115 ... 230 VAC
    • Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
    • Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
    • Option CO: 4 control outputs, serial RS232 interface
    • Option CR: 4 control outputs, serial RS485 interface
    • Option RL: 2 relay outputs
    Options can be combined.
  • Features

    • 2 Incremental inputs with format A, /A, B, /B
    • Differential, single-ended HTL / RS422
    • Input frequency up to 1 MHz
    • Power supply 18 ... 30 VDC
    • 5 / 24 VDC auxiliary output for encoder supply
    • 3.78 x 1.89-inch norm panel housing and IP65 protection
    • Bright and high-contrast display with event-dependent color variations
    • Emulation of a 7-segment display inclusively icons and units
    • Intuitive and easy parameterization by plain text and touchscreen
    • Multi-functional device for speed, process time, timer, counter or velocity application
    • Operating modes such as scaling, average filter, start-up suppression
    • Linearization with 24 control points

    Options

    • Option AC: Power supply 115 ... 230 VAC
    • Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
    • Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
    • Option CO: 4 control outputs, serial RS232 interface
    • Option CR: 4 control outputs, serial RS485 interface
    • Option RL: 2 relay outputsOptions can be combined.
  • Features

    • Pulse input with format A, B, 90° [HTL] or A, /A, B, /B [RS422], also possible for single-channel
    • Input frequency up to 500 kHz
    • 2 output relays with potential-free change-over contact (forward, reward and zero motion)
    • 2 transistor outputs with High-Side-Driver, short-circuit-proof
    • Power supply 17 ... 30 VDC
    • Snap-on housing for top hat rail (according to EN 60715)
    • DIL switch for setup of input characteristic and definition of standstill
  • Features

    • Pulse input with format A, B, 90° [HTL] or A, /A, B, /B [RS422], also possible for single-channel
    • Input frequency up to 1 MHz
    • 3 output relays
    • 14 Bit analog output for ±10 V or 0/4 ... 20 mA
    • Power supply 17 ... 30 VDC
    • Auxiliary voltage output +5 V for the supply of TTL encoders
    • Snap-on housing for top hat rail (according to EN 60715)
    • LCD display, backlighted
    • Setup via keys or via PC by serial RS232 interface
  • Features

    • Pulse input with format A, B, 90° [HTL] or A, /A, B, /B [RS422], also possible for single-channel
    • Input frequency up to 1 MHz
    • 3 fast transistor switching outputs [PNP]
    • 14 bit analog output for ±10 V or 0/4 ... 20 mA
    • Power supply 17 ... 30 VDC
    • Auxiliary voltage output +5 V for the supply of TTL encoders
    • Snap-on housing for top hat rail (according to EN 60715)
    • LCD display, backlighted
    • Setup via keys or via PC by serial RS232 interface
  • Features

    • Pulse input with format A, B, 90° [HTL] or A, /A, B, /B [RS422], also possible for single-channel
    • Input frequency up to 1 MHz
    • 14 bit analog output for ±10 V or 0/4 ... 20 mA
    • Power supply 17 ... 30 VDC
    • Auxiliary voltage output +5 V for the supply of TTL encoders
    • Snap-on housing for top hat rail (according to EN 60715)
    • LCD display, backlighted
    • Setup via keys or via PC by serial RS232 interface
  • Features

    • Pulse input with format A, B, 90° [HTL] or A, /A, B, /B [RS422], also possible for single-channel
    • Input frequency up to 1 MHz
    • 3 output relays
    • Power supply 17 ... 30 VDC
    • Auxiliary voltage output +5 V for the supply of TTL encoders
    • Snap-on housing for top hat rail (according to EN 60715)
    • LCD display, backlighted
    • Setup via keys or via PC by serial RS232 interface
  • Features

    • Pulse input with format A, B, 90° [HTL] or A, /A, B, /B [RS422], also possible for single-channel
    • Input frequency up to 1 MHz
    • 3 output relays
    • Power supply 17 ... 30 VDC
    • Auxiliary voltage output +5 V for the supply of TTL encoders
    • Snap-on housing for top hat rail (according to EN 60715)
    • LCD display, backlighted
    • Setup via keys or via PC by serial RS232 interface
  • Features

    • EtherCAT interface
    • 3 control inputs for remote release
    • Power supply 18 ... 30 VDC
    • Norm panel housing with 96 x 48 mm and protection class IP65
    • Bright and high-contrast graphic display with event-dependent color variants
    • Emulation of a 7-segment display with symbols, units and bargraph
    • Intuitive and simple parameterization through plain text and touchscreen
  • Features

    • EtherNET/IP interface
    • 3 control inputs for remote release
    • Power supply 18 ... 30 VDC
    • Norm panel housing with 96 x 48 mm and protection class IP65
    • Bright and high-contrast graphic display with event-dependent color variants
    • Emulation of a 7-segment display with symbols, units and bargraph
    • Intuitive and simple parameterization through plain text and touchscreen
  • Features

    • Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
    • 4 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
    • BUS interface for quick and easy connection of the modules
    • Power supply 10 ... 30 VDC
    • Signal delay time 160 ns
    • Input level at RS422 / TTL (differential voltage > 0.5 V),
    • Input level at HTL differential (differential voltage > 2 V),
    • Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
    • Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
    • Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
    • Dimensions W x H x D = 34 x 118 x 140 mm (1,34 x 4,65 x 5,51")
  • Features

    • Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
    • 8 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
    • BUS interface for quick and easy connection of the modules
    • Power supply 10 ... 30 VDC
    • Signal delay time 160 ns
    • Input level at RS422 / TTL (differential voltage > 0.5 V),
    • Input level at HTL differential (differential voltage > 2 V),
    • Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
    • Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
    • Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
    • Dimensions W x H x D = 54 x 118 x 140 mm (2,13 x 4,65 x 5,51")
  • Features

    • Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
    • 4 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
    • BUS interface for quick and easy connection of the modules
    • Power supply 10 ... 30 VDC
    • Signal delay time 160 ns
    • Input level at RS422 / TTL (differential voltage > 0.5 V),
    • Input level at HTL differential (differential voltage > 2 V),
    • Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
    • Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
    • Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
    • Dimensions W x H x D = 34 x 118 x 140 mm (1,34 x 4,65 x 5,51")
  • Features

    • Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
    • 8 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
    • BUS interface for quick and easy connection of the modules
    • Power supply 10 ... 30 VDC
    • Signal delay time 160 ns
    • Input level at RS422 / TTL (differential voltage > 0.5 V),
    • Input level at HTL differential (differential voltage > 2 V),
    • Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
    • Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
    • Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
    • Dimensions W x H x D = 54 x 118 x 140 mm (2,13 x 4,65 x 5,51")
  • Features

    • Sub-D-9 connectors (male) on both sides
    • cable length 10 cm (approx. 3.4")
  • Features

    • Pulse input with format A, B, Z [HTL single-ended, TTL single-ended] or A, /A, B, /B, Z, /Z [RS422, HTL differential]
    • 4 control inputs for HTL, PNP signals [10 ... 30 VDC]
    • Input and output frequency up to 1 MHz
    • 3 incremental outputs with format A, /A, B, /B, Z, /Z, Push-Pull, [8 … 29 VDC]
    • Power supply 9 ... 30 VDC
    • Snap-on housing for top-hat rail (acc. EN 60715)
    • Multiplier/divisor adjustable as quotient F1 / F2
    • Multiplication/division without cumulative residual errors
    • Additional functions such as jog, trim, offset and reference
  • Features

    • Pulse input with format A, B, 90° [HTL] or A, /A, B, /B, Z, /Z [RS422]
    • 4 control inputs for PNP signals [10 ... 30 VDC]
    • Input and output frequency up to 1 MHz
    • Pulse output with format A, /A, B, /B, Z, /Z and push-pull characteristic, [5 ... 30 VDC]
    • Power supply 11 ... 30 VDC
    • Snap-on housing for top-hat rail (according to EN 60715)
    • LCD backlighted
    • Setup via keys, RS232
    • The device multiplies an incoming frequency by a proportional factor F1 and a reciprocal factor F2. The two factors F1 and F2 are adjustable in the range of 0.0005 to 9.9999
    • All operation modes provide error-free frequency conversion, with full consideration of the A / B phase and direction of the quadrature signals, therefore no cumulative errors, even with continuous changes of directions and vibrations
    • Zero pulse generator: the frequency multiplier generates at the output an index signal with an adjustable pulse interval, which can be synchronized as needed with the zero pulse at the input

Title