Features

  • 2 universal 16-bit analog inputs for ±10 V or 0/4 … 20 mA
  • 3 control inputs for HTL / PNP signals
  • Power supply 18 ... 30 VDC
  • 24 V auxiliary output for encoder supply
  • High accuracy reference output 10 V for potentiometers > 1 kOhm
  • 3.78 x 1.89-inch norm panel housing and IP65 protection
  • Bright and high-contrast display with event-dependent color variations
  • Emulation of a 7-segment display inclusively icons and units
  • Intuitive and easy parameterization by plain text and touchscreen
  • Operating modes for visualization of INPUT 1, INPUT 2 or combinations of IN1 + IN2, IN1 - IN2, IN1 x IN2, IN1: IN2
  • Numerous features, e. g. Ttara, filters, averaging
  • Linearization with 24 control points

Option IO (= IO-Link Device)

  • Data transfer via COM3 (230,4 kBaud)
  • Cycle times < 3 msec
  • Process data IN 32 Byte (6 x process values from AX350): - Analog value 1 (scaled / linearized) and unit - Analog value 2 (scaled / linearized) and unit - Analog value 1 (scaled / linearized) with totalisation and unit - Analog value 2 (scaled / linearized) with totalisation and unit - Shortcut analogue value 1 (scaled / linearized) with analogue value 2  (scaled / linearized) and unit - Shortcut totalisator analogue value 1 (scaled / linearized) with totalisator analogue value 2 (scaled / linearized) and unit
  • Process data Out 8 Byte (2 x IO-Link process values to AX350): - IOL process value Out 1 with scaling, adjustable decimal point and programmable units - IOL process values Out 2 with scaling, adjustable decimal point and programmable units

Combinable with further options:

  • Option AC: Power supply 115 ... 230 VAC
  • Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
  • Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
  • Option CO: 4 control outputs, serial RS232 interface
  • Option CR: 4 control outputs, serial RS485 interface
  • Option RL: 2 relay outputs