• Features

    • 1 encoder input programmable with format A, /A, B, /B, Z, /Z [TTL / RS422] or optionally A, B, Z [HTL]
    • Input frequency 750 kHz [TTL] or 300 kHz [HTL]
    • 2 pulse outputs with format A, /A, B, /B, Z, /Z with individual adjustable output levels 5 V [TTL] or 10 ... 30 V [HTL]
    • Power supply optionally 5 VDC or 10 ... 30 VDC
    • Auxiliary voltage +5 V for encoder supply 10 ... 30 VDC
  • Features

    • 2 pulse inputs with format  A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422]
    • Input frequency up to 250 kHz for asymmetrical and up to 1 MHz for symmetric signals
    • 2 control inputs for HTL / PNP signals [10 ... 30 VDC]
    • 2 output channels with format  A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422], each output adjustable separately
    • Power supply 12 ... 30 VDC
    • Snap-on housing for top-hat rail (according to EN 60715)
  • Features

    • 1 pulse input with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422]
    • Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
    • 4 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
    • BUS interface for quick and easy expansion of the number of outputs
    • Power supply 10 ... 30 VDC
    • Signal delay time 160 ns
    • Input level at RS422 / TTL (differential voltage > 0.5 V),
    • Input level at HTL differential (differential voltage > 2 V),
    • Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
    • Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
    • Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
    • Dimensions W x H x D = 34 x 118 x 140 mm (1,34 x 4,65 x 5,51")
  • Features

    • 1 pulse input with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422]
    • Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
    • 8 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
    • BUS interface for quick and easy expansion of the number of outputs
    • Power supply 10 ... 30 VDC
    • Signal delay time 160 ns
    • Input level at RS422 / TTL (differential voltage > 0.5 V),
    • Input level at HTL differential (differential voltage > 2 V),
    • Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
    • Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
    • Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
    • Dimensions W x H x D = 54 x 118 x 140 mm (2,13 x 4,65 x 5,51")
  • Features

    • 1 pulse input with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422]
    • Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
    • 8 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
    • BUS interface for quick and easy expansion of the number of outputs
    • Power supply 10 ... 30 VDC
    • Signal delay time 160 ns
    • Input level at RS422 / TTL (differential voltage > 0.5 V),
    • Input level at HTL differential (differential voltage > 2 V),
    • Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
    • Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
    • Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
    • Dimensions W x H x D = 54 x 118 x 140 mm (2,13 x 4,65 x 5,51")
  • Features

    • 4 analog inputs for ±10 V or 0/4 ... 20 mA (2x current / 2x voltage)
    • optionally 3 control inputs for PNP signals [10 ... 30 VDC]
    • IO link interface
    • Power supply 12 ... 30 VDC
    • Compact housing for mounting on 35 mm DIN rail (according to EN 60715)
  • Features

    • 1 Strain gauge input
    • 3 VDC and 10 VDC bridge voltage per sensor connection
    • 1 … 10 mV sensitivity
    • optionally 3 control inputs for PNP signals [10 ... 30 VDC]
    • IO link interface
    • Power supply 12 ... 30 VDC
    • Compact housing for mounting on 35 mm DIN rail (according to EN 60715)
  • Features

    • 1 incremental input (A, /A, B, /B)
    • for HTL/TTL/RS422 for NPN/PNP/NAMUR encoders and sensors
    • optionally 3 control inputs for PNP signals [10 ... 30 VDC]
    • IO link interface
    • Power supply 12 ... 30 VDC
    • Compact housing for mounting on 35 mm DIN rail (according to EN 60715)
  • Features

    • 1 SSI input (10 … 32 bit)
    • for single-turn and multiturn encoders
    • optionally 3 control inputs for PNP signals [10 ... 30 VDC]
    • IO link interface
    • Power supply 12 ... 30 VDC
    • Compact housing for mounting on 35 mm DIN rail (according to EN 60715)
  • Features

    • SSI input  with format DATA+, DATA-, CLOCK+, CLOCK- up to 32 Bit
    • Impulse inputs A, B [HTL], A, /A, B, /B [RS422, HTL]
    • 3 control inputs (Hold) for PNP signals [10 ... 30 VDC]
    • Start-stop interface for absolute transducers and magnetostrictive sensors
    • Input frequency up to 1 MHz
    • 25-bit parallel output push-pull in BCD, binary or Gray code format
    • Power supply 18 ... 30 VDC
    • Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)
  • Features

    • SSI input with format  DATA+, DATA-, CLOCK+, CLOCK- up to 25-bit
    • Clock frequency up to 1 MHz
    • Control input (hold) for PNP signals [10 ... 30 VDC]
    • 25-bit parallel output with push-pull characteristic with format  BCD, binary or Gray-Code
    • Power supply 18 ... 30 VDC
    • Snap-on housing for top-hat rail (according to EN 60715)
    • Serial RS232 input
  • Features

    • Pulse input in format A, /A, B, /B, Z, /Z [RS422, HTL]
    • Pulse input in format A, B, Z [HTL]
    • Input frequency up to 1 MHz
    • Pulse output in format A, /A, B, /B, Z, /Z [RS422, HTL]
    • Pulse output in format A, B, Z [HTL]
    • Power supply 9 ... 30 VDC
    • Settings via DIL switches
    • Level conversion (RS422, HTL single-ended, HTL differential, TTL and vice versa)
    • Division of two-track A / B pulses with adjustable ratio 1: 1 to 1: 4096
    • Division of the Z pulse with adjustable ratio 1: 1 to 1: 256
    • External HTL signals for various functions
    • Implementation between the two types of representations for the direction of rotation (A / B 90 °, A/B Dir and vice versa, Division possible)
    • Snap-on housing for top-hat rail (acc. EN 60715)
    • Dimension (B x H X T) 22,5 x 102 x 102 mm
  • Features

    • SSI input DATA+, DATA-, CLOCK+, CLOCK- [RS422], 32 Bit
    • SSI clock frequency up to 1 MHz
    • Analog output ±10 V or 0/4 ... 20 mA, 16 Bit
    • Power supply 18 ... 30 VDC
    • Snap-on housing for top-hat rail (according to EN 60715)
    • Setup via operator software OS6.0
    • Serial RS232- / RS485 interface
    • Pulse inputs A, B [HTL], A, /A, B, /B [RS422, HTL]
    • Start-stop interface for absolute transducers and magnetostrictive sensors
    • USB interface and RS232/RS485 interface for configuration and serial readout
  • Features

    • 4 independent input channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422], also possible for single-channel
    • 4 output channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422]
    • Maximum input frequency 1 MHz
    • Very short conversion time < 300 ns
    • Optical wavelength 1300 nm
    • Transmission distance up to 3000 meters
    • Power supply 5 VDC (for LW213)
    • Power supply 10 ... 30 VDC (for LW213-1, LW213-2, LW213-3)
    • Snap-on housing for top-hat rail (according to EN 60715)
    • Pre-configured optical fibres are available
  • Features

    • 4 independent input channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422], also possible for single channel
    • 4 output channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422]
    • Maximum input frequency 1 MHz
    • Very short conversion time < 300 ns
    • Optical wavelength 1300 nm
    • Transmission distances up to 3000 meters
    • Power supply 5 VDC (for LW214)
    • Power supply 10 ... 30 VDC (for LW214-1, LW214-2)
    • Snap-on housing for top-hat rail (according to EN 60715)
    • Pre-configured optical fibers are available
  • Features

    • 4 independent input channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422], also possible for single channel
    • 4 output channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422]
    • Maximum input frequency 1 MHz
    • Very short conversion time < 300 ns
    • Optical wavelength 850 nm
    • Transmission distance up to 2000 meters
    • Power supply 5 VDC (for LW215)
    • Power supply 10 ... 30 VDC (for LW215-1, LW215-2, LW216-3)
    • Snap-on housing for top-hat rail (according to EN 60715)
    • Pre-configured optical fibers are available
  • Features

    • 4 independent input channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422], also possible for single channel
    • 4 output channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422]
    • Maximum input frequency 1 MHz
    • Very short conversion time < 300 ns
    • Optical wavelength 850 nm
    • Transmission distance up to 2000 meters
    • Power supply 5 VDC (for LW216)
    • Power supply 10 ... 30 VDC (for LW216-1, LW216-2)
    • Snap-on housing for top-hat rail (according to EN 60715)
    • Pre-configured optical fibers are available
  • Features

    • 1 SSI input / output channel [RS422] with format DATA+, DATA-, CLOCK+, CLOCK-
    • 1 Error input (LW217) resp. 1 open-drain-output (LW218)
    • Maximum input frequency 1 MHz
    • Very short conversion time < 300 nsec.
    • Optical wavelength 850 nm
    • Transmission distance up to 2000 meters
    • Power supply 5 VDC (for LW217)
    • Power supply 10 ... 30 VDC (for LW217-1)
    • Free adjustable SSI resolution from 1 ... 99 bit
    • Snap-on housing for top-hat rail (according to EN 60715)
    • Pre-configured optical fibres are available
  • Features

    • 1 SSI input / output channel [RS422] with format DATA+, DATA-, CLOCK+, CLOCK-
    • 1 open-drain-output (LW218)
    • Maximum input frequency 1 MHz
    • Very short conversion time < 300 ns
    • Optical wavelength 1300 nm
    • Transmission distance up to 2000 meters
    • Power supply 5 VDC (for LW218)
    • Power supply 10 ... 30 VDC (for LW218-1)
    • Free adjustable SSI resolution from 1 ... 99 bit
    • Snap-on housing for top-hat rail (according to EN 60715)
    • Glass fibre cables are available ready-assembled
  • Features

    • Internal power supply 3,3 V
    • Ambient temperature 0° C ... +60° C / 32° F ... 140° F (operating), -40° C ... +70° C / -40 ... 158° F (storage)
    • 9600 Bit/s ... 12 MBit/s Baud rates
    • SUB-D-9-pin female, galvanically isolated
  • Features

    • Internal power supply 3,3 V
    • Ambient temperature 0° C ... +60° C (operating), -40° C ... +70° C (storage)
    • 100 MBit/s Vollduplex
    • 2 Ethernet-Ports RJ45 with integrated switch, galvanically isolated
  • Features

    • Start-stop interface for absolute transducers and magnetostrictive sensors
    • SSI input in the format DATA +, DATA-, CLOCK +, CLOCK- up to 32 bits
    • 3 control inputs (hold) for PNP signals [10 ... 30 VDC]
    • Pulse inputs A, B [HTL], A, / A, B, / B [RS422, HTL]
    • Input frequency up to 1 MHz
    • 25-bit parallel output push-pull in BCD, binary or Gray code format
    • Power supply 18 ... 30 VDC
    • Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)
  • Features

    • 20-bit parallel input  with format  BCD, binary or Gray-Code
    • Input frequency: fast encoder 5 kHz, auto-transmit / data logging 0.5 kHz
    • 4 status outputs, with push-pull characteristics, short-circuit-proof  [5 ... 30 VDC]
    • Power supply 10 ... 30 VDC
    • Snap-on housing for top-hat rail (according to EN 60715)
    • Serial RS232 / RS485 interface
  • Features

    • Pulse input with format A, B, Z [HTL] (10 ... 30 V)
    • Input frequency max. 200 kHz
    • Pulse output with format A, /A, B, /B, Z, /Z [RS422 / TTL]
    • Power supply 5 VDC
    • Converts HTL levels (A / B / Z) in TTL / RS422, incl. the inverted signals
    • Converts also static/separate directional information into a dual channel A / B signal with a 90° phase shift
    • Open print version with plastic snap-on housing for top-hat rail (according to EN 60715)
  • Features

    • Pulse input with format A, /A, B, /B, Z, /Z [TTL / RS422]
    • Input frequency max. 200 kHz
    • Pulse output with format A, B, Z [HTL]
    • Power supply 10 ... 30 VDC
    • Converts TTL / RS422 signals (A, /A, B, /B, Z, /Z) in  HTL format with an output level of 10 ... 30 VDC
    • Generates additionally an A / B directional information with 90° phase shift‚ a static HIGH / LOW directional signal or separate directional pulses
    • Open print version with plastic snap-on housing for top-hat rail (according to EN 60715)

Title