f/U resp. f/I Signal Converter Analog >>> SSI / Frequency / Serial / IO-Link
The small, cost-efficient, but extremely powerful f/I or f/U converters are designed for cabinet installation. They are used to convert analogue standard signals (V or mA) into an incremental (HTL, RS422 / TTL), absolute (SSI) or serial (RS232 / RS485) output format. The converters shown below can be mounted on a DIN rail in the control cabinet utilizing snap-on mounting.
Further possibilities for the conversion of analogue signals are also available with our process displays of the series AX.
Scalable 14 bit analog input for ±10 V or 0/4 ... 20 mA
4 control inputs for PNP signals [10 ... 30 VDC]
Pulse output with format A, B, 90° [HTL] or A, /A, B, /B, Z, /Z [RS422]
SSI output with format DATA+, DATA-, CLOCK+, CLOCK- up to 25 bit
Power supply 12 ... 30 VDC
Snap-on housing for top-hat rail (according to EN 60715)
Various user modes: Programmable V / f characteristics, programmable curves with optionally repeating curve cycles, additional control functions similar to a “motorized potentiometer”
USB, RS232 and RS485 interface for programming and serial readout of the conversion result and other internal registers
Adjustable filter functions as well as operator programmable linearization curves
Printer mode for automatic data transfer of internal registers to a data logger or PC