• Features

    • Hollow Shaft Small Size
    • Resolution (Counts/Turn): 1,000∼12,000C/T
    • Output Phase: A, B, Z, EU, EV, EW Phase
    • Max Response Frequency: 200kHz
    • Supply Voltage: DC+5V
    • Consumption Current: 200mA Max
    • Output Form: Line Driver
    • Mounting Tolerance: Radial 0.05mm TIR Max, Axial 0.2mm Max, Shaft Runout 0.1°Max
    • Starting Torque: 9.8×10-3N⋅m (100gf⋅cm Max)
    • Protection: IP=40
    • Operating Temp. Range: -20∼+85°C
    • Vibration: 49m/s2(5G)
    • Shock: 980m/s2(100G)
    • Mass: 0.3kg Max
  • Features

    • Adopts R/D conversion based on a proven digital tracking system.
    • Low cost, small size and lightweight.
    • Abnormality detection - Capable of detecting abnormal resolver signals, breaking of resolver signals, abnormal R/D conversion and abnormally high temperature of a IC
    • Built-in self-test - Conducts a self-test on R/D conversion and abnormality detection・Realization of system/cost reduction based on all-in-one concepts
    • Integrated with an excitation amplifier (Output current: 1 OmA rms/20mA rms)
    • Integrated with an operation clock
    • Enhancement of functions corresponding to various applications
    • Requires no phase adjustment to excitation signals (Allowable range: Within土45゜)
    • Variable setting of controlling bandwidth (fBW) (Selectable from 7 types of fixed values or automatic adjustment)
    • Capable of digital conversion of linear hall IC signals and R/D parallel connections to resolvers
    • Output redundancy (Triple redundancy-Parallel/Pulse/Serial output)
  • Features

    • Compact size, Lightweight, Low cost
    • Package area :1/2 (compared to AU6802N1)
    • Advanced failure check functions
    • Enhanced error detection functions (Square sum, Wire cut, PLL unlock, Over-temp)
    • BIST Built-ln Self Test functions
    • Excitation Amp (currency controlled) incorporated
    • All-in-one concept to reduce total system cost
    • Can handle Sine/Cosine DC resolver signals