• Features

    • Scalable 14-bit analog input for 0 ... 10 V or 0/4 ... 20 mA
    • Power supply 24 VDC
    • Miniature norm panel housing
    • 5 digits LED display with 8 mm height
    • Display range -19999 ... 99999, adjustable zero and full-scale value
    • Latch input to freeze the display, minimum/maximum record memory
    • Easy to set up with only two front keys and menu support
    • Delivery includes adapter frame for 50 x 25 mm cut out and label set with dimensions
    • Front dimension 48 x 24 x 59 mm (1.89 x 0.945 x 2.322")
  • Features

    • 2 universal 16-bit analogue inputs for ±10 V or 0/4 … 20 mA
    • 3 control inputs for HTL / PNP signals
    • Power supply 18 ... 30 VDC
    • 24 V auxiliary output for encoder supply
    • High accuracy reference output 10 V for potentiometers > 1 kOhm
    • 3.78 x 1.89-inch norm panel housing and IP65 protection
    • Bright and high-contrast display with event-dependent color variations
    • Emulation of a 7-segment display inclusively icons and units
    • Intuitive and easy parameterization by plain text and touchscreen
    • Operating modes for visualization of INPUT 1, INPUT 2 or combinations of IN1 + IN2, IN1 - IN2, IN1 x IN2, IN1: IN2
    • Numerous features, e. g. tara, filters, averaging
    • Linearization with 24 control points

    Options

    • Option AC: Power supply 115 ... 230 VAC
    • Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
    • Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
    • Option CO: 4 control outputs, serial RS232 interface
    • Option CR: 4 control outputs, serial RS485 interface
    • Option RL: 2 relay outputs
    • Option IO: IO-Link Device V1.1
  • Features

    • Individual scalable process or speed indicator
    • Dual channel frequency indicator for visualization of the encoder frequency
    • Display of alarm and error codes
    • Touch screen with intuitive menu guidance
    • 1.54" OLED Display (128 x 64 Pixel)
    • Dimension: 50 x 80 x 15 mm (1,97 x 3,15 x  0,59")
  • Features

    • Simple parameterization of motrona safety devices
    • Editing, saving and loading of parameters
    • Individual scalable process or speed indicator
    • Dual channel frequency indicator for visualization of the encoder frequency
    • Touch screen with intuitive menu guidance
    • 1.54" OLED Display (128 x 64 Pixel)
    • Dimension: 50 x 80 x 15 mm (1,97 x 3,15 x  0,59")
  • Features

    • Internal power supply 3,3 V
    • Ambient temperature 0° C ... +60° C / 32° F ... 140° F (operating), -40° C ... +70° C / -40° F ... 158° F (storage)
    • 10, 20, 50, 100, 125, 250, 500, 800 und 1000 kbps Baud rates
    • SUB-D-9-pin male, galvanically isolated
  • Features

    • USB to RS232 converter (compatible with all existing Windows versions)
    • Serial RS232 cable (for connection between the converter and motrona unit)
    • One connector Sub-D-9 (male)
    • One connector Sub-D-9 (female)
    • Length 3 m (approx. 10 feet)
    • Windows driver CD enclosed
  • Features

    • Solder connection
    • Metallised plastic enclosure
    • Mounting screws included
  • Features

    • Solder connection
    • Metallised plastic enclosure
    • Mounting screws included
  • Features

    • Solder connection
    • Metallised plastic enclosure
    • Mounting screws included
  • Features

    • Solder connection
    • Metallised plastic enclosure
    • Mounting screws included
  • Features

    • SIL3 and PLe certification
    • Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
    • 2 encoder inputs with format SIN+, SIN-, COS+, COS- [1 Vss]
    • 2 pulse inputs with format A, /A, B, /B [RS422]
    • 2 pulse- or control inputs with format A, B, 90° [HTL / PNP] (for rotary encoder, proximity switches or commands)
    • Input frequency up to 500 kHz
    • Forced-guided redundant output relay (NO)
    • 4 control outputs with push-pull characteristic, short-circuit-proof, [HTL], each inverse and redundant
    • Safety related 14 bit analog output for 4 ... 20 mA (scalable)
    • With signal splitter
    • Power supply 18 ... 30 V
    • Compact housing for 35 mm mounting top hat rail
    • (according to EN 60715)
    • Setup via USB port by operator software or plug-in display and programming unit BG230 (accessories)
  • Features

    • SIL3 and PLe certification
    • Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
    • 2 encoder inputs with format SIN+, SIN-, COS+, COS- [1 Vss]
    • 2 pulse inputs with format A, /A, B, /B [RS422]
    • 2 pulse- or control inputs with format A, B, 90° [HTL / PNP] (for rotary encoder, proximity switches or commands)
    • Input frequency up to 500 kHz
    • Forced-guided redundant output relay (NO)
    • 4 control outputs with push-pull characteristics, short-circuit-proof, [HTL], each inverse and redundant
    • Safety-related 14-bit analogue output for 4 ... 20 mA (scalable)
    • Power supply 18 ... 30 V
    • Compact housing for 35 mm mounting top-hat rail (according to EN 60715)
    • Setup via USB port by operator software or plug-in display and programming unit BG230 (accessories)
  • Features

    • SIL3 and PLe certification
    • Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
    • 2 encoder input with format SIN+, SIN-, COS+, COS- [1 Vss]
    • 2 pulse- or control inputs with format A, B, 90° [HTL / PNP] (for rotary encoder, proximity switches or commands)
    • Input frequency up to 500 kHz
    • Forced-guided redundant output relay (NO)
    • 4 control outputs with push-pull characteristic, short-circuit-proof, [HTL], each inverse and redundant
    • Safety-related 14-bit analogue output for 4 ... 20 mA (scalable)
    • With signal splitter
    • Power supply 18 ... 30 V
    • Compact housing for 35 mm mounting top hat rail (according to EN 60715)
    • Setup via USB port by operator software or plug-in display and programming unit BG230
  • Features

    • SIL3/PLe certification
    • Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
    • 2 encoder input with format SIN+, SIN-, COS+, COS- [1 Vss]
    • 2 pulse inputs with format A, /A, B, /B [RS422]
    • 2 pulse- or control inputs with format A, B, 90° [HTL / PNP] (for rotary encoder, proximity switches or commands)
    • Input frequency up to 500 kHz
    • Forced-guided redundant output relay (NO)
    • 4 control outputs with push-pull characteristic, short-circuit-proof, [HTL], each inverse and redundant
    • Safety-related 14-bit analog output for 4 ... 20 mA (scalable)
    • Power supply 18 ... 30 V
    • Compact housing for 35 mm mounting top hat rail (according to EN 60715)
    • Setup via USB port by operator software or plug-in display and programming unit BG230
  • Features

    • SIL3 and PLe certification
    • Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
    • 2 incremental encoder inputs with format A, /A, B, /B, Z, /Z [HTL differencial, HTL single ended, RS422]
    • 8 control inputs [HTL / PNP]
    • Input frequency up to 500 kHz
    • 2 relay outputs 5... 250 VAC / VDC (NO)
    • 4 x 2 control outputs with push-pull characteristic, short-circuit-proof, [HTL], antivalent or equivalent redundant or simply used
    • Safety related 14 bit analog output for 4 ... 20 mA (scalable)
    • Signal splitter
    • Power supply 18 ... 30 V
    • Wire monitoring of the sensor signals
    • Compact housing for 35 mm mounting top hat rail (according to EN 60715)
    • USB interface in combination with the user interface OS6.0 for the parameterization of the safety speed monitor
    • BG200 operator panel for easy parameterization and display (optional)
  • Features

    • SIL3 and PLe certification (depends on the used encoder/sensor arrangement)
    • Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
    • 1 incremental encoder input with format A, /A, B, /B, Z, /Z [HTL differencial, RS422]
    • 8 control inputs [HTL / PNP]
    • Input frequency up to 500 kHz
    • 2 relay outputs 5... 250 VAC / VDC (NO)
    • 4 x 2 control outputs with push-pull characteristic, short-circuit-proof, [HTL], antivalent or equivalent redundant or simply used
    • Safety related 14 bit analog output for 4 ... 20 mA (scalable)
    • Signal splitter
    • Power supply 18 ... 30 V
    • Wire monitoring of the sensor signals
    • Compact housing for 35 mm mounting top hat rail (according to EN 60715)
    • USB interface in combination with the user interface OS6.0 for the parameterization of the safety speed monitor
    • BG200 operator panel for easy parameterization and display (optional)
  • Features

    • Pulse input with format A, B, 90° [HTL] or A, /A, B, /B [RS422], also possible for single-channel
    • Input frequency up to 500 kHz
    • 2 output relays with potential-free change-over contact (forward, reward and zero motion)
    • 2 transistor outputs with High-Side-Driver, short-circuit-proof
    • Power supply 17 ... 30 VDC
    • Snap-on housing for top hat rail (according to EN 60715)
    • DIL switch for setup of input characteristic and definition of standstill
  • Features

    • Pulse input with format A, B, 90° [HTL] or A, /A, B, /B [RS422], also possible for single-channel
    • Input frequency up to 1 MHz
    • 3 output relays
    • 14 Bit analog output for ±10 V or 0/4 ... 20 mA
    • Power supply 17 ... 30 VDC
    • Auxiliary voltage output +5 V for the supply of TTL encoders
    • Snap-on housing for top hat rail (according to EN 60715)
    • LCD display, backlighted
    • Setup via keys or via PC by serial RS232 interface
  • Features

    • Pulse input with format A, B, 90° [HTL] or A, /A, B, /B [RS422], also possible for single-channel
    • Input frequency up to 1 MHz
    • 3 fast transistor switching outputs [PNP]
    • 14 bit analog output for ±10 V or 0/4 ... 20 mA
    • Power supply 17 ... 30 VDC
    • Auxiliary voltage output +5 V for the supply of TTL encoders
    • Snap-on housing for top hat rail (according to EN 60715)
    • LCD display, backlighted
    • Setup via keys or via PC by serial RS232 interface
  • Features

    • Pulse input with format A, B, 90° [HTL] or A, /A, B, /B [RS422], also possible for single-channel
    • Input frequency up to 1 MHz
    • 14 bit analog output for ±10 V or 0/4 ... 20 mA
    • Power supply 17 ... 30 VDC
    • Auxiliary voltage output +5 V for the supply of TTL encoders
    • Snap-on housing for top hat rail (according to EN 60715)
    • LCD display, backlighted
    • Setup via keys or via PC by serial RS232 interface
  • Features

    • Pulse input with format A, B, 90° [HTL] or A, /A, B, /B [RS422], also possible for single-channel
    • Input frequency up to 1 MHz
    • 3 output relays
    • Power supply 17 ... 30 VDC
    • Auxiliary voltage output +5 V for the supply of TTL encoders
    • Snap-on housing for top hat rail (according to EN 60715)
    • LCD display, backlighted
    • Setup via keys or via PC by serial RS232 interface
  • Features

    • Pulse input with format A, B, 90° [HTL] or A, /A, B, /B [RS422], also possible for single-channel
    • Input frequency up to 1 MHz
    • 3 output relays
    • Power supply 17 ... 30 VDC
    • Auxiliary voltage output +5 V for the supply of TTL encoders
    • Snap-on housing for top hat rail (according to EN 60715)
    • LCD display, backlighted
    • Setup via keys or via PC by serial RS232 interface
  • Features

    • Sub-D-9 connectors (male) on both sides
    • cable length 10 cm (approx. 3.4")
  • Features

    • 4 analog inputs for ±10 V or 0/4 ... 20 mA (2x current / 2x voltage)
    • optionally 3 control inputs for PNP signals [10 ... 30 VDC]
    • IO link interface
    • Power supply 12 ... 30 VDC
    • Compact housing for mounting on 35 mm DIN rail (according to EN 60715)
  • Features

    • 4 independent input channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422], also possible for single-channel
    • 4 output channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422]
    • Maximum input frequency 1 MHz
    • Very short conversion time < 300 ns
    • Optical wavelength 1300 nm
    • Transmission distance up to 3000 meters
    • Power supply 5 VDC (for LW213)
    • Power supply 10 ... 30 VDC (for LW213-1, LW213-2, LW213-3)
    • Snap-on housing for top-hat rail (according to EN 60715)
    • Pre-configured optical fibres are available

Title