• Features

    • 1 SSI input / output channel [RS422] with format DATA+, DATA-, CLOCK+, CLOCK-
    • 1 open-drain-output (LW218)
    • Maximum input frequency 1 MHz
    • Very short conversion time < 300 ns
    • Optical wavelength 1300 nm
    • Transmission distance up to 2000 meters
    • Power supply 5 VDC (for LW218)
    • Power supply 10 ... 30 VDC (for LW218-1)
    • Free adjustable SSI resolution from 1 ... 99 bit
    • Snap-on housing for top-hat rail (according to EN 60715)
    • Glass fibre cables are available ready-assembled
  • Features

    • 4 pulse inputs with format  A, /A, B, /B [RS422]
    • 4 scalable 12-bit analog inputs for ±10 V or 0/4 ... 20 mA
    • 8 control inputs for PNP signals [10 ... 30 VDC]
    • 4 scalable 12-bit analog outputs for ±10 V or 0/4 ... 20 mA
    • Short loop time (depending on application)
    • Power supply 18 ... 35 VDC
    • Snap-on housing for top-hat rail (according to EN 60715)
    • Setup via Windows operator software (free of charge)
    • OnBoard interfaces: RS232 and CANopen
  • Features

    • The MC800 hardware is a universal motion controller, which serves for sophisticated control tasks in today’s machine engineering and drive technology. This motion controller can cover a wide application range due to the function features and settings of the equipped control firmware.
    • Typical control applications are e.g. drive synchronization of a master and slave axis, index and print mark evaluation, rotating cross cutters, flying and eccentric shears, label printing machines and many more.
    • The unique feature of the MC800 is the integrated tandem drive controller. This enables to reach the acceleration requirements of heavy loads by splitting the necessary power to two independent drives.
    • Further features are the flexible and combinable input configuration for different types of encoders, measuring systems and sensors, the high frequency range up to 2 MHz and the adaptive interface architecture.
    • Due to an extremely short position loop time of 250 µs, a self-optimizing polynomial motion profile, and excellent accuracy - even at high line speeds, the MC800 ensures a very smooth motion with maximum protection of the mechanical parts.
  • Features

    • Internal power supply 3,3 V
    • Ambient temperature 0° C ... +60° C / 32° F ... 140° F (operating), -40° C ... +70° C / -40 ... 158° F (storage)
    • 9600 Bit/s ... 12 MBit/s Baud rates
    • SUB-D-9-pin female, galvanically isolated
  • Features

    • Internal power supply 3,3 V
    • Ambient temperature 0° C ... +60° C (operating), -40° C ... +70° C (storage)
    • 100 MBit/s Vollduplex
    • 2 Ethernet-Ports RJ45 with integrated switch, galvanically isolated
  • Features

    • Start-stop interface for absolute transducers and magnetostrictive sensors
    • SSI input in the format DATA +, DATA-, CLOCK +, CLOCK- up to 32 bits
    • 3 control inputs (hold) for PNP signals [10 ... 30 VDC]
    • Pulse inputs A, B [HTL], A, / A, B, / B [RS422, HTL]
    • Input frequency up to 1 MHz
    • 25-bit parallel output push-pull in BCD, binary or Gray code format
    • Power supply 18 ... 30 VDC
    • Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)
  • Features

    • 20-bit parallel input  with format  BCD, binary or Gray-Code
    • Input frequency: fast encoder 5 kHz, auto-transmit / data logging 0.5 kHz
    • 4 status outputs, with push-pull characteristics, short-circuit-proof  [5 ... 30 VDC]
    • Power supply 10 ... 30 VDC
    • Snap-on housing for top-hat rail (according to EN 60715)
    • Serial RS232 / RS485 interface
  • Features

    • 2 pulse inputs with format A, B, 90° [HTL] or A, /A, B, /B [RS422]
    • 4 control inputs for HTL / PNP / NPN / Namur signals [10 ... 30 VDC]
    • Input frequency up to 300 kHz
    • 4 fast transistor outputs, push-pull, short-circuit-proof [5 … 30 VDC]
    • 1 scalable 14-bit analog output (±10 V or 0/4 … 20 mA)
    • Loop time approx. 250 µs
    • Defining incremental dimensions via keyboard
    • Power supply 24 VAC and 17 … 40 VDC
    • Compact norm panel housing (according to EN 60715)
    • Top hat rail mounting by using SM300 support brackets (option)
    • Setup via keys or via PC by serial RS232 interface
    • PROFIBUS connection via mMotrona gateway PB251
  • Features

    • 2 pulse inputs with format A, B, 90° [HTL] or A, /A, B, /B [RS422]
    • 4 control inputs for HTL / PNP / NPN / Namur signals [10 ... 30 VDC]
    • Input frequency up to 300 kHz
    • 4 fast transistor outputs, push-pull, short-circuit-proof [5 … 30 VDC]
    • 1 scalable 14-bit analog output (±10 V or 0/4 … 20 mA)
    • Loop time approx. 250 µs
    • Defining incremental dimensions via keyboard or BCD decade switch on the front
    • Power supply 24 VAC and 17 … 40 VDC
    • Compact norm panel housing (according to EN 60715)
    • Top hat rail mounting by using SM600 support brackets (option)
    • Setup via keys or via PC by serial RS232 interface
    • PROFIBUS connection via Motrona gateway PB251
    • Dimension 96 x 96 x 140 mm (3,78 x 3,78 x 5,51")
  • Features

    • Pulse input with format A, B, Z [HTL] (10 ... 30 V)
    • Input frequency max. 200 kHz
    • Pulse output with format A, /A, B, /B, Z, /Z [RS422 / TTL]
    • Power supply 5 VDC
    • Converts HTL levels (A / B / Z) in TTL / RS422, incl. the inverted signals
    • Converts also static/separate directional information into a dual channel A / B signal with a 90° phase shift
    • Open print version with plastic snap-on housing for top-hat rail (according to EN 60715)
  • Features

    • Pulse input with format A, /A, B, /B, Z, /Z [TTL / RS422]
    • Input frequency max. 200 kHz
    • Pulse output with format A, B, Z [HTL]
    • Power supply 10 ... 30 VDC
    • Converts TTL / RS422 signals (A, /A, B, /B, Z, /Z) in  HTL format with an output level of 10 ... 30 VDC
    • Generates additionally an A / B directional information with 90° phase shift‚ a static HIGH / LOW directional signal or separate directional pulses
    • Open print version with plastic snap-on housing for top-hat rail (according to EN 60715)
  • Features

    • 1 pulse input with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422]
    • Input frequency up to 500 kHz
    • 1 pulse output with format A, /A, B, /B, Z, /Z [RS422, HTL]
    • Power supply 5 ... 30 VDC
    • Potential separation between input and output
    • Possibility to convert A, B / 90 ° directional information into static directional signal and vice versa
    • Connections on the input as well as on the output either via sub-D plugs or plug-in screw terminals (parallel connections)
    • Snap-on housing for top-hat rail (according to EN 60715)
  • Features

    • Start-stop interface for absolute transducers and magnetostrictive sensors
    • Adjustable frequency of the init pulses from 62.5 Hz to 5 kHz
    • Analog output ± 10 V, 0/4 ... 20 mA, 16 bit
    • Power supply 18 ... 30 VDC
    • Compact housing for mounting on a 35 mm top-hat rail (according to EN 60715)
    • Simple parameterization via the OS6.0 user interface
    • Serial RS232 / RS485 interface
    • Pulse inputs A, B [HTL], A, /A, B, /B [RS422, HTL]
    • SSI input DATA+, DATA-, CLOCK+, CLOCK- [RS422], 32 Bit
    • USB interface and RS232/RS485 interface for configuration and serial readout
  • Features

    • Encoder input with format SIN+, SIN-, COS+, COS-, REF+, REF- [1 Vss]
    • Control input „Error Release“ for PNP signals [10 ... 30 VDC]
    • Input frequency up to 400 kHz
    • Pulse output with format A, /A, B, /B, Z, /Z [RS422] or with format A, B, 90° [HTL]
    • Output frequency up to 4 MHz [RS422]
    • Control output „Error“ with push-pull characteristic, short-circuit-proof, [5 ... 30 VDC]
    • Power supply 18 ... 30 VDC
    • Snap-on housing for top-hat rail (according to EN 60715)
    • Adjustable multiplier for interpolation rates from 1:5 to 1:50
    • Adjustable divider 1:1 – 1:255 to reduce the output frequency
  • Features

    • Encoder input with format SIN+, SIN-, COS+, COS-, REF+, REF- [1 Vss]
    • Control input „Error Release“ for PNP signals [10 ... 30 VDC]
    • Input frequency up to 400 kHz
    • Pulse output with format A, /A, B, /B, Z, /Z [RS422]
    • Pulse output with format A, B, 90° [HTL]
    • Output frequency up to 100 kHz [HTL], up to 4 MHz [RS422]
    • Control output „Error“ with push-pull characteristic, short-circuit-proof, [5 ... 30 VDC]
    • Power supply 18 ... 30 VDC
    • Snap-on housing for top-hat rail (according to EN 60715)
    • Adjustable multiplier for interpolation rates from 1:5 to 1:50
    • Adjustable divider 1:1 – 1:128 to reduce the output frequency
  • Features

    • 1 encoder input with format SIN+, SIN-, COS+, COS-, REF+, REF- [1 Vss]
    • Maximum sinus input frequency 500 kHz with max. 200 ns conversion time
    • 2 signal outputs with format SIN+, SIN-, COS+, COS-, REF+, REF- [1 Vss]
    • 2 pulse outputs with format A, /A, B, /B, Z, /Z [RS422, TTL, HTL]
    • Power supply 17 ... 30 VDC
    • Snap-on housing for top-hat rail (according to EN 60715)
  • Features

    • 1 encoder input with format SIN+, SIN-, COS+, COS-, REF+, REF- [1 Vss]
    • Maximum sinus input frequency 500 kHz with max. 200 ns conversion time
    • 4 signal outputs with format SIN+, SIN-, COS+, COS-, REF+, REF- [1 Vss]
    • Power supply 17 ... 30 VDC
    • Snap-on housing for top-hat rail (according to EN 60715)
  • Features

    • Scalable 14 bit analog input  for ±10 V or 0/4 ... 20 mA
    • 4 control inputs for PNP signals [10 ... 30 VDC]
    • Pulse output with format  A, B, 90° [HTL] or A, /A, B, /B, Z, /Z [RS422]
    • SSI output with format  DATA+, DATA-, CLOCK+, CLOCK- up to 25 bit
    • Power supply 12 ... 30 VDC
    • Snap-on housing for top-hat rail (according to EN 60715)
    • Various user modes: Programmable V / f characteristics,  programmable curves with optionally repeating curve cycles, additional control functions similar to a “motorized potentiometer”
    • USB, RS232 and RS485 interface for programming and serial readout of the conversion result and other internal registers
    • Adjustable filter functions as well as operator programmable linearization curves
    • Printer mode for automatic data transfer of internal registers to a data logger or PC
  • Features

    • Pulse inputs A, B [HTL], A, / A, B, / B [RS422, HTL]
    • SSI input in the format DATA +, DATA-, CLOCK +, CLOCK- up to 32 bits
    • Start-stop interface for absolute transducers and magnetostrictive sensors
    • 3 control inputs (hold) for PNP signals [10 ... 30 VDC]
    • Input frequency up to 1 MHz
    • 25-bit parallel output push-pull in BCD, binary or Gray code format
    • Power supply 18 ... 30 VDC
    • Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)
  • Features

    • Pulse inputs A, B [HTL], A, /A, B, /B [RS422, HTL]
    • Input frequency up to 1 MHz [RS422], 200 kHz [HTL]
    • Analog output ±10 V or 0/4 ... 20 mA, 16 Bit
    • Power supply 18 ... 30 VDC
    • Snap-on housing for top-hat rail (according to EN 60715)
    • Setup via operator software OS6.0
    • Serial RS232- / RS485 interface
    • SSI input DATA+, DATA-, CLOCK+, CLOCK- [RS422], 32 Bit
    • Start-stop interface for absolute transducers and magnetostrictive sensors
    • USB interface and RS232/RS485 interface for configuration and serial readout
  • Features

    • Adopts R/D conversion based on a proven digital tracking system.
    • Low cost, small size and lightweight.
    • Abnormality detection - Capable of detecting abnormal resolver signals, breaking of resolver signals, abnormal R/D conversion and abnormally high temperature of a IC
    • Built-in self-test - Conducts a self-test on R/D conversion and abnormality detection・Realization of system/cost reduction based on all-in-one concepts
    • Integrated with an excitation amplifier (Output current: 1 OmA rms/20mA rms)
    • Integrated with an operation clock
    • Enhancement of functions corresponding to various applications
    • Requires no phase adjustment to excitation signals (Allowable range: Within土45゜)
    • Variable setting of controlling bandwidth (fBW) (Selectable from 7 types of fixed values or automatic adjustment)
    • Capable of digital conversion of linear hall IC signals and R/D parallel connections to resolvers
    • Output redundancy (Triple redundancy-Parallel/Pulse/Serial output)
  • Features

    • Compact size, Lightweight, Low cost
    • Package area :1/2 (compared to AU6802N1)
    • Advanced failure check functions
    • Enhanced error detection functions (Square sum, Wire cut, PLL unlock, Over-temp)
    • BIST Built-ln Self Test functions
    • Excitation Amp (currency controlled) incorporated
    • All-in-one concept to reduce total system cost
    • Can handle Sine/Cosine DC resolver signals

Title