• Features

    • Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
    • 4 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
    • BUS interface for quick and easy connection of the modules
    • Power supply 10 ... 30 VDC
    • Signal delay time 160 ns
    • Input level at RS422 / TTL (differential voltage > 0.5 V),
    • Input level at HTL differential (differential voltage > 2 V),
    • Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
    • Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
    • Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
    • Dimensions W x H x D = 34 x 118 x 140 mm (1,34 x 4,65 x 5,51")
  • Features

    • Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
    • 8 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
    • BUS interface for quick and easy connection of the modules
    • Power supply 10 ... 30 VDC
    • Signal delay time 160 ns
    • Input level at RS422 / TTL (differential voltage > 0.5 V),
    • Input level at HTL differential (differential voltage > 2 V),
    • Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
    • Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
    • Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
    • Dimensions W x H x D = 54 x 118 x 140 mm (2,13 x 4,65 x 5,51")
  • Features

    • Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
    • 4 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
    • BUS interface for quick and easy connection of the modules
    • Power supply 10 ... 30 VDC
    • Signal delay time 160 ns
    • Input level at RS422 / TTL (differential voltage > 0.5 V),
    • Input level at HTL differential (differential voltage > 2 V),
    • Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
    • Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
    • Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
    • Dimensions W x H x D = 34 x 118 x 140 mm (1,34 x 4,65 x 5,51")
  • Features

    • Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
    • 8 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
    • BUS interface for quick and easy connection of the modules
    • Power supply 10 ... 30 VDC
    • Signal delay time 160 ns
    • Input level at RS422 / TTL (differential voltage > 0.5 V),
    • Input level at HTL differential (differential voltage > 2 V),
    • Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
    • Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
    • Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
    • Dimensions W x H x D = 54 x 118 x 140 mm (2,13 x 4,65 x 5,51")
  • Features

    • Control input with format [HTL]
    • 2 SSI inputs with format [RS422]
    • Cutt-off frequency 100 kHz ... 1 MHz
    • 2 encoder inputs, short-circuit-proof
    • 1 SSI output with format [RS422]
    • Power supply 12 ... 30 V DC
    • Current consumption (unloaded) 50 mA
    • Encoder supply 2 x 125mA (Vin – 2 V) short-circuit-proof
    • Delay / Output / Input100 ns
    • Operation temperature : 0 ... 45 °C (32 ... 113 °F)
    • SSI pause time min. 25 ns
    • Switching time is synchronized automatically with the next SSI break
    • Cascadable for more SSI encoders
    • All connections via pluggable screw terminal block
    • Snap-on housing for top-hat rail (according to EN 60715)
    • LEDs for indication of the input pulses
    • Dimension W x H x D = 22,5 x 121 x 112 mm (8.86 x 47.64 x 44.09'')
    • Plastic housing incl. plug
  • Features

    • 2 x 6 control outputs für HTL / PNP signals
    • Pulse inputs with format A, /A, B, /B, Z, /Z [RS422]
    • Input frequency up to 1 MHz
    • 2 encoder outputs, short-circuit-proof [TTL / RS422]
    • Power supply 12 ... 30 VDC
    • Current consumption (unloaded) 30 mA
    • Encoder supply 5 ... 35 VDC (extern connect to +VAUX)
    • Operation temperature: 0 ... 60 °C (32 ... 140°F)
    • Latency time < 250ns
    • Channel switching  < 1 ms
    • Open plastic housing for top-hat rail (according to EN 60715)
    • LEDs for indication of the input pulses
  • Features

    • 1 pulse input with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422]
    • Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
    • 2 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
    • BUS interface for quick and easy expansion of the number of outputs
    • Power supply 10 ... 30 VDC
    • Signal delay time 160 ns
    • Input level at RS422 / TTL (differential voltage > 0.5 V),
    • Input level at HTL differential (differential voltage > 2 V),
    • Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
    • Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
    • Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
    • Dimensions W x H x D = 34 x 118 x 140 mm (1,34 x 4,65 x 5,51")
  • Features

    • 1 pulse input with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422]
    • Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
    • 4 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
    • BUS interface for quick and easy expansion of the number of outputs
    • Power supply 10 ... 30 VDC
    • Signal delay time 160 ns
    • Input level at RS422 / TTL (differential voltage > 0.5 V),
    • Input level at HTL differential (differential voltage > 2 V),
    • Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
    • Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
    • Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
    • Dimensions W x H x D = 34 x 118 x 140 mm (1,34 x 4,65 x 5,51")
  • Features

    • 1 pulse input with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422]
    • Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
    • 8 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
    • BUS interface for quick and easy expansion of the number of outputs
    • Power supply 10 ... 30 VDC
    • Signal delay time 160 ns
    • Input level at RS422 / TTL (differential voltage > 0.5 V),
    • Input level at HTL differential (differential voltage > 2 V),
    • Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
    • Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
    • Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
    • Dimensions W x H x D = 54 x 118 x 140 mm (2,13 x 4,65 x 5,51")
  • Features

    • 1 pulse input with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422]
    • Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
    • 8 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
    • BUS interface for quick and easy expansion of the number of outputs
    • Power supply 10 ... 30 VDC
    • Signal delay time 160 ns
    • Input level at RS422 / TTL (differential voltage > 0.5 V),
    • Input level at HTL differential (differential voltage > 2 V),
    • Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
    • Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
    • Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
    • Dimensions W x H x D = 54 x 118 x 140 mm (2,13 x 4,65 x 5,51")
  • Features

    • 1 encoder input programmable with format A, /A, B, /B, Z, /Z [TTL / RS422] or optionally A, B, Z [HTL]
    • Input frequency 750 kHz [TTL] or 300 kHz [HTL]
    • 2 pulse outputs with format A, /A, B, /B, Z, /Z with individual adjustable output levels 5 V [TTL] or 10 ... 30 V [HTL]
    • Power supply optionally 5 VDC or 10 ... 30 VDC
    • Auxiliary voltage +5 V for encoder supply 10 ... 30 VDC
  • Features

    • 2 pulse inputs with format  A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422]
    • Input frequency up to 250 kHz for asymmetrical and up to 1 MHz for symmetric signals
    • 2 control inputs for HTL / PNP signals [10 ... 30 VDC]
    • 2 output channels with format  A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422], each output adjustable separately
    • Power supply 12 ... 30 VDC
    • Snap-on housing for top-hat rail (according to EN 60715)
  • Features

    • 1 pulse input with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422]
    • Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
    • 4 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
    • BUS interface for quick and easy expansion of the number of outputs
    • Power supply 10 ... 30 VDC
    • Signal delay time 160 ns
    • Input level at RS422 / TTL (differential voltage > 0.5 V),
    • Input level at HTL differential (differential voltage > 2 V),
    • Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
    • Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
    • Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
    • Dimensions W x H x D = 34 x 118 x 140 mm (1,34 x 4,65 x 5,51")
  • Features

    • 1 pulse input with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422]
    • Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
    • 8 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
    • BUS interface for quick and easy expansion of the number of outputs
    • Power supply 10 ... 30 VDC
    • Signal delay time 160 ns
    • Input level at RS422 / TTL (differential voltage > 0.5 V),
    • Input level at HTL differential (differential voltage > 2 V),
    • Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
    • Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
    • Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
    • Dimensions W x H x D = 54 x 118 x 140 mm (2,13 x 4,65 x 5,51")
  • Features

    • 1 pulse input with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422]
    • Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
    • 8 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
    • BUS interface for quick and easy expansion of the number of outputs
    • Power supply 10 ... 30 VDC
    • Signal delay time 160 ns
    • Input level at RS422 / TTL (differential voltage > 0.5 V),
    • Input level at HTL differential (differential voltage > 2 V),
    • Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
    • Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
    • Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
    • Dimensions W x H x D = 54 x 118 x 140 mm (2,13 x 4,65 x 5,51")
  • Features

    • 1 SSI input (10 … 32 bit)
    • for single-turn and multiturn encoders
    • optionally 3 control inputs for PNP signals [10 ... 30 VDC]
    • IO link interface
    • Power supply 12 ... 30 VDC
    • Compact housing for mounting on 35 mm DIN rail (according to EN 60715)
  • Features

    • SSI input  with format DATA+, DATA-, CLOCK+, CLOCK- up to 32 Bit
    • Impulse inputs A, B [HTL], A, /A, B, /B [RS422, HTL]
    • 3 control inputs (Hold) for PNP signals [10 ... 30 VDC]
    • Start-stop interface for absolute transducers and magnetostrictive sensors
    • Input frequency up to 1 MHz
    • 25-bit parallel output push-pull in BCD, binary or Gray code format
    • Power supply 18 ... 30 VDC
    • Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)
  • Features

    • SSI input DATA+, DATA-, CLOCK+, CLOCK- [RS422], 32 Bit
    • SSI clock frequency up to 1 MHz
    • Analog output ±10 V or 0/4 ... 20 mA, 16 Bit
    • Power supply 18 ... 30 VDC
    • Snap-on housing for top-hat rail (according to EN 60715)
    • Setup via operator software OS6.0
    • Serial RS232- / RS485 interface
    • Pulse inputs A, B [HTL], A, /A, B, /B [RS422, HTL]
    • Start-stop interface for absolute transducers and magnetostrictive sensors
    • USB interface and RS232/RS485 interface for configuration and serial readout
  • Features

    • SSI input with format DATA+, DATA-, CLOCK+, CLOCK-
    • SSI clock frequencies up to 1 MHz
    • Master or Slave operation
    • For single-turn and multi-turn encoders with 10 … 32 Bit
    • 3 control inputs for HTL / PNP signals
    • Power supply 18 ... 30 VDC
    • 24 V auxiliary output for encoder supply
    • 3.78 x 1.89-inch norm panel housing and IP65 protection
    • Bright and high-contrast display with event-dependent color variations
    • Emulation of a 7-segment display inclusively icons and units
    • Intuitive and easy parameterization by plain text and touchscreen
    • Operating modes such as scaling and bit blanking
    • Linearization with 24 control points

    Options

    • Option AC: Power supply 115 ... 230 VAC
    • Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
    • Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
    • Option CO: 4 control outputs, serial RS232 interface
    • Option CR: 4 control outputs, serial RS485 interface
    • Option RL: 2 relay outputsOptions can be combined.
  • Features

    • SSI input with format DATA+, DATA-, CLOCK+, CLOCK-
    • SSI clock frequencies up to 1 MHz
    • Master or Slave operation
    • For single-turn and multi-turn encoders with 10 … 32 Bit
    • 3 control inputs for HTL / PNP signals
    • Power supply 18 ... 30 VDC
    • 5 / 24 V auxiliary output for encoder supply
    • 3.78 x 1.89-inch norm panel housing and IP65 protection
    • Bright and high-contrast display with event-dependent color variations
    • Emulation of a 7-segment display inclusively icons and units
    • Intuitive and easy parameterization by plain text and touchscreen
    • Operating modes such as scaling, bit blanking and wire break monitoring
    • Linearization with 24 control points

    Options

    • Option AC: Power supply 115 ... 230 VAC
    • Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
    • Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
    • Option CO: 4 control outputs, serial RS232 interface
    • Option CR: 4 control outputs, serial RS485 interface
    • Option RL: 2 relay outputs
    Options can be combined
  • Features

    • Pulse input with format A, B, 90° [HTL], single channel as an option
    • HTL input for encoder and sensors with NPN / PNP or NAMUR switching characteristics
    • Input frequency up to 250 kHz
    • 3 control inputs for HTL / PNP signals
    • Power supply 18 ... 30 VDC
    • 24 V auxiliary output for encoder supply
    • 3.78 x 1.89-inch norm panel housing and IP65 protection
    • Bright and high-contrast display with event-dependent colour variations
    • Emulation of a 7-segment display inclusively icons and units
    • Intuitive and easy parameterization by plain text and touchscreen
    • Multi-function device for use as speedometer/tachometer, pulse counter/position indicator, number counter and total counter
    • Operating modes such as scaling, average filter, start-up suppression
    • Linearization with 24 control points

    Options

    • Option AC: Power supply 115 ... 230 VAC
    • Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
    • Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
    • Option CO: 4 control outputs, serial RS232 interface
    • Option CR: 4 control outputs, serial RS485 interface
    • Option RL: 2 relay outputs
    Options can be combined.
  • Features

    • Incremental input with format A, /A, B, /B
    • Differential, single-ended HTL / RS422
    • Input frequency up to 1 MHz
    • 3 control inputs for HTL / PNP signals
    • Power supply 18 ... 30 VDC
    • 24 V auxiliary output for encoder supply
    • 3.78 x 1.89-inch norm panel housing and IP65 protection
    • Bright and high-contrast display with event-dependent colour variations
    • Emulation of a 7-segment display inclusively icons and units
    • Intuitive and easy parameterization by plain text and touchscreen
    • Multi-function device for use as speedometer/tachometer, pulse counter/position indicator, number counter and total counter
    • Operating modes such as scaling, average filter, start-up suppression
    • Linearization with 24 control points

    Options

    • Option AC: Power supply 115 ... 230 VAC
    • Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
    • Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
    • Option CO: 4 control outputs, serial RS232 interface
    • Option CR: 4 control outputs, serial RS485 interface
    • Option RL: 2 relay outputs
    Options can be combined.
  • Features

    • 20-bit parallel input  with format  BCD, binary or Gray-Code
    • Input frequency: fast encoder 5 kHz, auto-transmit / data logging 0.5 kHz
    • 4 status outputs, with push-pull characteristics, short-circuit-proof  [5 ... 30 VDC]
    • Power supply 10 ... 30 VDC
    • Snap-on housing for top-hat rail (according to EN 60715)
    • Serial RS232 / RS485 interface
  • Features

    • 1 encoder input with format SIN+, SIN-, COS+, COS-, REF+, REF- [1 Vss]
    • Maximum sinus input frequency 500 kHz with max. 200 ns conversion time
    • 2 signal outputs with format SIN+, SIN-, COS+, COS-, REF+, REF- [1 Vss]
    • 2 pulse outputs with format A, /A, B, /B, Z, /Z [RS422, TTL, HTL]
    • Power supply 17 ... 30 VDC
    • Snap-on housing for top-hat rail (according to EN 60715)

Title