• Features

    • Individual scalable process or speed indicator
    • Dual channel frequency indicator for visualization of the encoder frequency
    • Display of alarm and error codes
    • Touch screen with intuitive menu guidance
    • 1.54" OLED Display (128 x 64 Pixel)
    • Dimension: 50 x 80 x 15 mm (1,97 x 3,15 x  0,59")
  • Features

    • Simple parameterization of motrona safety devices
    • Editing, saving and loading of parameters
    • Individual scalable process or speed indicator
    • Dual channel frequency indicator for visualization of the encoder frequency
    • Touch screen with intuitive menu guidance
    • 1.54" OLED Display (128 x 64 Pixel)
    • Dimension: 50 x 80 x 15 mm (1,97 x 3,15 x  0,59")
  • Features

    • Internal power supply 3,3 V
    • Ambient temperature 0° C ... +60° C / 32° F ... 140° F (operating), -40° C ... +70° C / -40° F ... 158° F (storage)
    • 10, 20, 50, 100, 125, 250, 500, 800 und 1000 kbps Baud rates
    • SUB-D-9-pin male, galvanically isolated
  • Features

    • USB to RS232 converter (compatible with all existing Windows versions)
    • Serial RS232 cable (for connection between the converter and motrona unit)
    • One connector Sub-D-9 (male)
    • One connector Sub-D-9 (female)
    • Length 3 m (approx. 10 feet)
    • Windows driver CD enclosed
  • Features

    • Solder connection
    • Metallised plastic enclosure
    • Mounting screws included
  • Features

    • Solder connection
    • Metallised plastic enclosure
    • Mounting screws included
  • Features

    • 6-wire connection for one strain gauge full bridge sensor
    • 4 control inputs [HTL/PNP]
    • 1 analog output ±10 V, 0/4 ... 20 mA, 16 bit
    • 4 control outputs for signalling different operation states
    • Power supply 18 ... 30 VDC
    • Functions for scaling and linking the sensor signals (e.g. A+B, A-B, ...)
    • Adjustable bridge voltage per sensor from 3 VDC ... 10 VDC
    • Sensitivity of the sensor inputs 1 ... 10 mV
    • Transmission of the sensor data via RS485
    • Programming via USB and the user interface OS (freeware)
    • Protection class IP20
    • Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)
  • Features

    • 6-wire connection for two independent strain gauge full bridge sensors
    • 4 control inputs [HTL/PNP]
    • 2 independent analog outputs ±10 V, 0/4 ... 20 mA, 16 bit
    • 4 control outputs for signalling different operation states
    • Power supply 18 ... 30 VDC
    • Functions for scaling and linking the sensor signals (e.g. A+B, A-B, ...)
    • Adjustable bridge voltage per sensor from 3 VDC ... 10 VDC
    • Sensitivity of the sensor inputs 1 ... 10 mV
    • Transmission of the sensor data via RS485
    • Programming via USB and the user interface OS (freeware)
    • Protection class IP20
    • Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)
  • Features

    • Solder connection
    • Metallised plastic enclosure
    • Mounting screws included
  • Features

    • Solder connection
    • Metallised plastic enclosure
    • Mounting screws included
  • Features

    • SIL3 and PLe certification
    • Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
    • 2 encoder inputs with format SIN+, SIN-, COS+, COS- [1 Vss]
    • 2 pulse inputs with format A, /A, B, /B [RS422]
    • 2 pulse- or control inputs with format A, B, 90° [HTL / PNP] (for rotary encoder, proximity switches or commands)
    • Input frequency up to 500 kHz
    • Forced-guided redundant output relay (NO)
    • 4 control outputs with push-pull characteristic, short-circuit-proof, [HTL], each inverse and redundant
    • Safety related 14 bit analog output for 4 ... 20 mA (scalable)
    • With signal splitter
    • Power supply 18 ... 30 V
    • Compact housing for 35 mm mounting top hat rail
    • (according to EN 60715)
    • Setup via USB port by operator software or plug-in display and programming unit BG230 (accessories)
  • Features

    • SIL3 and PLe certification
    • Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
    • 2 encoder inputs with format SIN+, SIN-, COS+, COS- [1 Vss]
    • 2 pulse inputs with format A, /A, B, /B [RS422]
    • 2 pulse- or control inputs with format A, B, 90° [HTL / PNP] (for rotary encoder, proximity switches or commands)
    • Input frequency up to 500 kHz
    • Forced-guided redundant output relay (NO)
    • 4 control outputs with push-pull characteristics, short-circuit-proof, [HTL], each inverse and redundant
    • Safety-related 14-bit analogue output for 4 ... 20 mA (scalable)
    • Power supply 18 ... 30 V
    • Compact housing for 35 mm mounting top-hat rail (according to EN 60715)
    • Setup via USB port by operator software or plug-in display and programming unit BG230 (accessories)
  • Features

    • SIL3 and PLe certification
    • Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
    • 2 encoder input with format SIN+, SIN-, COS+, COS- [1 Vss]
    • 2 pulse- or control inputs with format A, B, 90° [HTL / PNP] (for rotary encoder, proximity switches or commands)
    • Input frequency up to 500 kHz
    • Forced-guided redundant output relay (NO)
    • 4 control outputs with push-pull characteristic, short-circuit-proof, [HTL], each inverse and redundant
    • Safety-related 14-bit analogue output for 4 ... 20 mA (scalable)
    • With signal splitter
    • Power supply 18 ... 30 V
    • Compact housing for 35 mm mounting top hat rail (according to EN 60715)
    • Setup via USB port by operator software or plug-in display and programming unit BG230
  • Features

    • SIL3/PLe certification
    • Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
    • 2 encoder input with format SIN+, SIN-, COS+, COS- [1 Vss]
    • 2 pulse inputs with format A, /A, B, /B [RS422]
    • 2 pulse- or control inputs with format A, B, 90° [HTL / PNP] (for rotary encoder, proximity switches or commands)
    • Input frequency up to 500 kHz
    • Forced-guided redundant output relay (NO)
    • 4 control outputs with push-pull characteristic, short-circuit-proof, [HTL], each inverse and redundant
    • Safety-related 14-bit analog output for 4 ... 20 mA (scalable)
    • Power supply 18 ... 30 V
    • Compact housing for 35 mm mounting top hat rail (according to EN 60715)
    • Setup via USB port by operator software or plug-in display and programming unit BG230
  • Features

    • SIL3 and PLe certification
    • Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
    • 2 incremental encoder inputs with format A, /A, B, /B, Z, /Z [HTL differencial, HTL single ended, RS422]
    • 8 control inputs [HTL / PNP]
    • Input frequency up to 500 kHz
    • 2 relay outputs 5... 250 VAC / VDC (NO)
    • 4 x 2 control outputs with push-pull characteristic, short-circuit-proof, [HTL], antivalent or equivalent redundant or simply used
    • Safety related 14 bit analog output for 4 ... 20 mA (scalable)
    • Signal splitter
    • Power supply 18 ... 30 V
    • Wire monitoring of the sensor signals
    • Compact housing for 35 mm mounting top hat rail (according to EN 60715)
    • USB interface in combination with the user interface OS6.0 for the parameterization of the safety speed monitor
    • BG200 operator panel for easy parameterization and display (optional)
  • Features

    • SIL3 and PLe certification (depends on the used encoder/sensor arrangement)
    • Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
    • 1 incremental encoder input with format A, /A, B, /B, Z, /Z [HTL differencial, RS422]
    • 8 control inputs [HTL / PNP]
    • Input frequency up to 500 kHz
    • 2 relay outputs 5... 250 VAC / VDC (NO)
    • 4 x 2 control outputs with push-pull characteristic, short-circuit-proof, [HTL], antivalent or equivalent redundant or simply used
    • Safety related 14 bit analog output for 4 ... 20 mA (scalable)
    • Signal splitter
    • Power supply 18 ... 30 V
    • Wire monitoring of the sensor signals
    • Compact housing for 35 mm mounting top hat rail (according to EN 60715)
    • USB interface in combination with the user interface OS6.0 for the parameterization of the safety speed monitor
    • BG200 operator panel for easy parameterization and display (optional)
  • Features

    • Pulse input with format A, B, 90° [HTL] or A, /A, B, /B [RS422], also possible for single-channel
    • Input frequency up to 500 kHz
    • 2 output relays with potential-free change-over contact (forward, reward and zero motion)
    • 2 transistor outputs with High-Side-Driver, short-circuit-proof
    • Power supply 17 ... 30 VDC
    • Snap-on housing for top hat rail (according to EN 60715)
    • DIL switch for setup of input characteristic and definition of standstill
  • Features

    • Pulse input with format A, B, 90° [HTL] or A, /A, B, /B [RS422], also possible for single-channel
    • Input frequency up to 1 MHz
    • 3 output relays
    • 14 Bit analog output for ±10 V or 0/4 ... 20 mA
    • Power supply 17 ... 30 VDC
    • Auxiliary voltage output +5 V for the supply of TTL encoders
    • Snap-on housing for top hat rail (according to EN 60715)
    • LCD display, backlighted
    • Setup via keys or via PC by serial RS232 interface
  • Features

    • Pulse input with format A, B, 90° [HTL] or A, /A, B, /B [RS422], also possible for single-channel
    • Input frequency up to 1 MHz
    • 3 fast transistor switching outputs [PNP]
    • 14 bit analog output for ±10 V or 0/4 ... 20 mA
    • Power supply 17 ... 30 VDC
    • Auxiliary voltage output +5 V for the supply of TTL encoders
    • Snap-on housing for top hat rail (according to EN 60715)
    • LCD display, backlighted
    • Setup via keys or via PC by serial RS232 interface
  • Features

    • Pulse input with format A, B, 90° [HTL] or A, /A, B, /B [RS422], also possible for single-channel
    • Input frequency up to 1 MHz
    • 14 bit analog output for ±10 V or 0/4 ... 20 mA
    • Power supply 17 ... 30 VDC
    • Auxiliary voltage output +5 V for the supply of TTL encoders
    • Snap-on housing for top hat rail (according to EN 60715)
    • LCD display, backlighted
    • Setup via keys or via PC by serial RS232 interface
  • Features

    • Pulse input with format A, B, 90° [HTL] or A, /A, B, /B [RS422], also possible for single-channel
    • Input frequency up to 1 MHz
    • 3 output relays
    • Power supply 17 ... 30 VDC
    • Auxiliary voltage output +5 V for the supply of TTL encoders
    • Snap-on housing for top hat rail (according to EN 60715)
    • LCD display, backlighted
    • Setup via keys or via PC by serial RS232 interface
  • Features

    • Pulse input with format A, B, 90° [HTL] or A, /A, B, /B [RS422], also possible for single-channel
    • Input frequency up to 1 MHz
    • 3 output relays
    • Power supply 17 ... 30 VDC
    • Auxiliary voltage output +5 V for the supply of TTL encoders
    • Snap-on housing for top hat rail (according to EN 60715)
    • LCD display, backlighted
    • Setup via keys or via PC by serial RS232 interface
  • Features

    • Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
    • 4 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
    • BUS interface for quick and easy connection of the modules
    • Power supply 10 ... 30 VDC
    • Signal delay time 160 ns
    • Input level at RS422 / TTL (differential voltage > 0.5 V),
    • Input level at HTL differential (differential voltage > 2 V),
    • Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
    • Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
    • Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
    • Dimensions W x H x D = 34 x 118 x 140 mm (1,34 x 4,65 x 5,51")
  • Features

    • Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
    • 8 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
    • BUS interface for quick and easy connection of the modules
    • Power supply 10 ... 30 VDC
    • Signal delay time 160 ns
    • Input level at RS422 / TTL (differential voltage > 0.5 V),
    • Input level at HTL differential (differential voltage > 2 V),
    • Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
    • Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
    • Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
    • Dimensions W x H x D = 54 x 118 x 140 mm (2,13 x 4,65 x 5,51")
  • Features

    • Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
    • 4 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
    • BUS interface for quick and easy connection of the modules
    • Power supply 10 ... 30 VDC
    • Signal delay time 160 ns
    • Input level at RS422 / TTL (differential voltage > 0.5 V),
    • Input level at HTL differential (differential voltage > 2 V),
    • Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
    • Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
    • Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
    • Dimensions W x H x D = 34 x 118 x 140 mm (1,34 x 4,65 x 5,51")

Title

Go to Top