• Features

    • 6-wire connection for one strain gauge full bridge sensor
    • 4 control inputs [HTL/PNP]
    • 1 analog output ±10 V, 0/4 ... 20 mA, 16 bit
    • 4 control outputs for signalling different operation states
    • Power supply 18 ... 30 VDC
    • Functions for scaling and linking the sensor signals (e.g. A+B, A-B, ...)
    • Adjustable bridge voltage per sensor from 3 VDC ... 10 VDC
    • Sensitivity of the sensor inputs 1 ... 10 mV
    • Transmission of the sensor data via RS485
    • Programming via USB and the user interface OS (freeware)
    • Protection class IP20
    • Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)
  • Features

    • 6-wire connection for two independent strain gauge full bridge sensors
    • 4 control inputs [HTL/PNP]
    • 2 independent analog outputs ±10 V, 0/4 ... 20 mA, 16 bit
    • 4 control outputs for signalling different operation states
    • Power supply 18 ... 30 VDC
    • Functions for scaling and linking the sensor signals (e.g. A+B, A-B, ...)
    • Adjustable bridge voltage per sensor from 3 VDC ... 10 VDC
    • Sensitivity of the sensor inputs 1 ... 10 mV
    • Transmission of the sensor data via RS485
    • Programming via USB and the user interface OS (freeware)
    • Protection class IP20
    • Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)
  • Features

    • Start-stop interface for absolute transducers and magnetostrictive sensors
    • Adjustable frequency of the init pulses from 62.5 Hz to 5 kHz
    • 3 control inputs for HTL / PNP signals
    • Power supply 18 ... 30 VDC
    • Auxiliary voltage output 24 VDC or 5 VDC for encoder supply
    • 8-decade LCD display (colour: red, green, yellow)
    • Resistive touchscreen
    • Standard housing with 96 x 48 mm and IP65 protection
    • Intuitive and easy parameterization by plain text and touchscreen
    • Numerous functions such as scaling, filter, zero offset, counting direction etc.
    • Linearization with 24 interpolation points

    Options

    • Option AC: Power supply 115 ... 230 VAC
    • Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
    • Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
    • Option CO: 4 control outputs, serial RS232 interface
    • Option CR: 4 control outputs, serial RS485 interface
    • Option RL: 2 relay outputs
    Options can be combined.
  • Features

    • 1 Strain gauge input
    • 3 VDC and 10 VDC bridge voltage per sensor connection
    • 1 … 10 mV sensitivity
    • optionally 3 control inputs for PNP signals [10 ... 30 VDC]
    • IO link interface
    • Power supply 12 ... 30 VDC
    • Compact housing for mounting on 35 mm DIN rail (according to EN 60715)
  • Features

    • SSI input with format DATA+, DATA-, CLOCK+, CLOCK-
    • SSI clock frequencies up to 1 MHz
    • Master or Slave operation
    • For single-turn and multi-turn encoders with 10 … 32 Bit
    • 3 control inputs for HTL / PNP signals
    • Power supply 18 ... 30 VDC
    • 24 V auxiliary output for encoder supply
    • 3.78 x 1.89-inch norm panel housing and IP65 protection
    • Bright and high-contrast display with event-dependent color variations
    • Emulation of a 7-segment display inclusively icons and units
    • Intuitive and easy parameterization by plain text and touchscreen
    • Operating modes such as scaling and bit blanking
    • Linearization with 24 control points

    Options

    • Option AC: Power supply 115 ... 230 VAC
    • Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
    • Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
    • Option CO: 4 control outputs, serial RS232 interface
    • Option CR: 4 control outputs, serial RS485 interface
    • Option RL: 2 relay outputsOptions can be combined.
  • Features

    • SSI input with format DATA+, DATA-, CLOCK+, CLOCK-
    • SSI clock frequencies up to 1 MHz
    • Master or Slave operation
    • For single-turn and multi-turn encoders with 10 … 32 Bit
    • 3 control inputs for HTL / PNP signals
    • Power supply 18 ... 30 VDC
    • 5 / 24 V auxiliary output for encoder supply
    • 3.78 x 1.89-inch norm panel housing and IP65 protection
    • Bright and high-contrast display with event-dependent color variations
    • Emulation of a 7-segment display inclusively icons and units
    • Intuitive and easy parameterization by plain text and touchscreen
    • Operating modes such as scaling, bit blanking and wire break monitoring
    • Linearization with 24 control points

    Options

    • Option AC: Power supply 115 ... 230 VAC
    • Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
    • Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
    • Option CO: 4 control outputs, serial RS232 interface
    • Option CR: 4 control outputs, serial RS485 interface
    • Option RL: 2 relay outputs
    Options can be combined

Title

Go to Top