• Features

    • Start-stop interface for absolute transducers and magnetostrictive sensors
    • SSI input in the format DATA +, DATA-, CLOCK +, CLOCK- up to 32 bits
    • 3 control inputs (hold) for PNP signals [10 ... 30 VDC]
    • Pulse inputs A, B [HTL], A, / A, B, / B [RS422, HTL]
    • Input frequency up to 1 MHz
    • 25-bit parallel output push-pull in BCD, binary or Gray code format
    • Power supply 18 ... 30 VDC
    • Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)
  • Features

    • 2 pulse inputs with format A, B, 90° [HTL] or A, /A, B, /B [RS422]
    • 4 control inputs for HTL / PNP / NPN / Namur signals [10 ... 30 VDC]
    • Input frequency up to 300 kHz
    • 4 fast transistor outputs, push-pull, short-circuit-proof [5 … 30 VDC]
    • 1 scalable 14-bit analog output (±10 V or 0/4 … 20 mA)
    • Loop time approx. 250 µs
    • Defining incremental dimensions via keyboard
    • Power supply 24 VAC and 17 … 40 VDC
    • Compact norm panel housing (according to EN 60715)
    • Top hat rail mounting by using SM300 support brackets (option)
    • Setup via keys or via PC by serial RS232 interface
    • PROFIBUS connection via mMotrona gateway PB251
  • Features

    • 2 pulse inputs with format A, B, 90° [HTL] or A, /A, B, /B [RS422]
    • 4 control inputs for HTL / PNP / NPN / Namur signals [10 ... 30 VDC]
    • Input frequency up to 300 kHz
    • 4 fast transistor outputs, push-pull, short-circuit-proof [5 … 30 VDC]
    • 1 scalable 14-bit analog output (±10 V or 0/4 … 20 mA)
    • Loop time approx. 250 µs
    • Defining incremental dimensions via keyboard or BCD decade switch on the front
    • Power supply 24 VAC and 17 … 40 VDC
    • Compact norm panel housing (according to EN 60715)
    • Top hat rail mounting by using SM600 support brackets (option)
    • Setup via keys or via PC by serial RS232 interface
    • PROFIBUS connection via Motrona gateway PB251
    • Dimension 96 x 96 x 140 mm (3,78 x 3,78 x 5,51")
  • Features

    • Start-stop interface for absolute transducers and magnetostrictive sensors
    • Adjustable frequency of the init pulses from 62.5 Hz to 5 kHz
    • Analog output ± 10 V, 0/4 ... 20 mA, 16 bit
    • Power supply 18 ... 30 VDC
    • Compact housing for mounting on a 35 mm top-hat rail (according to EN 60715)
    • Simple parameterization via the OS6.0 user interface
    • Serial RS232 / RS485 interface
    • Pulse inputs A, B [HTL], A, /A, B, /B [RS422, HTL]
    • SSI input DATA+, DATA-, CLOCK+, CLOCK- [RS422], 32 Bit
    • USB interface and RS232/RS485 interface for configuration and serial readout