• Features

    • Scalable 14-bit analog input for 0 ... 10 V or 0/4 ... 20 mA
    • Power supply 24 VDC
    • Miniature norm panel housing
    • 5 digits LED display with 8 mm height
    • Display range -19999 ... 99999, adjustable zero and full-scale value
    • Latch input to freeze the display, minimum/maximum record memory
    • Easy to set up with only two front keys and menu support
    • Delivery includes adapter frame for 50 x 25 mm cut out and label set with dimensions
    • Front dimension 48 x 24 x 59 mm (1.89 x 0.945 x 2.322")
  • Features

    • 2 universal 16-bit analog inputs for ±10 V or 0/4 … 20 mA
    • 3 control inputs for HTL / PNP signals
    • Power supply 18 ... 30 VDC
    • 24 V auxiliary output for encoder supply
    • High accuracy reference output 10 V for potentiometers > 1 kOhm
    • 3.78 x 1.89-inch norm panel housing and IP65 protection
    • Bright and high-contrast display with event-dependent color variations
    • Emulation of a 7-segment display inclusively icons and units
    • Intuitive and easy parameterization by plain text and touchscreen
    • Operating modes for visualization of INPUT 1, INPUT 2 or combinations of IN1 + IN2, IN1 - IN2, IN1 x IN2, IN1: IN2
    • Numerous features, e. g. Ttara, filters, averaging
    • Linearization with 24 control points

    Option IO (= IO-Link Device)

    • Data transfer via COM3 (230,4 kBaud)
    • Cycle times < 3 msec
    • Process data IN 32 Byte (6 x process values from AX350): - Analog value 1 (scaled / linearized) and unit - Analog value 2 (scaled / linearized) and unit - Analog value 1 (scaled / linearized) with totalisation and unit - Analog value 2 (scaled / linearized) with totalisation and unit - Shortcut analogue value 1 (scaled / linearized) with analogue value 2  (scaled / linearized) and unit - Shortcut totalisator analogue value 1 (scaled / linearized) with totalisator analogue value 2 (scaled / linearized) and unit
    • Process data Out 8 Byte (2 x IO-Link process values to AX350): - IOL process value Out 1 with scaling, adjustable decimal point and programmable units - IOL process values Out 2 with scaling, adjustable decimal point and programmable units

    Combinable with further options:

    • Option AC: Power supply 115 ... 230 VAC
    • Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
    • Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
    • Option CO: 4 control outputs, serial RS232 interface
    • Option CR: 4 control outputs, serial RS485 interface
    • Option RL: 2 relay outputs
  • Features

    • 4 analog inputs for ±10 V or 0/4 ... 20 mA (2x current / 2x voltage)
    • optionally 3 control inputs for PNP signals [10 ... 30 VDC]
    • IO link interface
    • Power supply 12 ... 30 VDC
    • Compact housing for mounting on 35 mm DIN rail (according to EN 60715)
  • Features

    • Scalable 14 bit analog input  for ±10 V or 0/4 ... 20 mA
    • 4 control inputs for PNP signals [10 ... 30 VDC]
    • Pulse output with format  A, B, 90° [HTL] or A, /A, B, /B, Z, /Z [RS422]
    • SSI output with format  DATA+, DATA-, CLOCK+, CLOCK- up to 25 bit
    • Power supply 12 ... 30 VDC
    • Snap-on housing for top-hat rail (according to EN 60715)
    • Various user modes: Programmable V / f characteristics,  programmable curves with optionally repeating curve cycles, additional control functions similar to a “motorized potentiometer”
    • USB, RS232 and RS485 interface for programming and serial readout of the conversion result and other internal registers
    • Adjustable filter functions as well as operator programmable linearization curves
    • Printer mode for automatic data transfer of internal registers to a data logger or PC

Title

Go to Top