• Features

    • MC700 is a universal motion controller for 1 to 4 axes, which can be assigned any motion control functions by loading firmware. Together with the firmware BY701 (see firmware), this controller offers excellent synchronous functions for 1 - 4 axes.
    • The firmware offers all conceivable possibilities for the synchronization of drives, including the influence of phase position and the relative position between the drives and numerous index and print mark functions.
    • Optionally, a "physical master" or the built-in "virtual master axis" with programmable speeds and ramps can be used as the master drive.
    • The number of successive axes can be extended arbitrarily via a cascading output.
    • MC700 controllers can be operated via an external control terminal, serial interface or optional via CANBUS (MC700/CI). PC operator software is included.
    • PROFIBUS connection possible via gateway PB251 (see accessories)
  • Features

    • 4 pulse inputs with format  A, /A, B, /B [RS422]
    • 4 scalable 12-bit analog inputs for ±10 V or 0/4 ... 20 mA
    • 8 control inputs for PNP signals [10 ... 30 VDC]
    • 4 scalable 12-bit analog outputs for ±10 V or 0/4 ... 20 mA
    • Short loop time (depending on application)
    • Power supply 18 ... 35 VDC
    • Snap-on housing for top-hat rail (according to EN 60715)
    • Setup via Windows operator software (free of charge)
    • OnBoard interfaces: RS232 and CANopen
  • Features

    • Start-stop interface for absolute transducers and magnetostrictive sensors
    • SSI input in the format DATA +, DATA-, CLOCK +, CLOCK- up to 32 bits
    • 3 control inputs (hold) for PNP signals [10 ... 30 VDC]
    • Pulse inputs A, B [HTL], A, / A, B, / B [RS422, HTL]
    • Input frequency up to 1 MHz
    • 25-bit parallel output push-pull in BCD, binary or Gray code format
    • Power supply 18 ... 30 VDC
    • Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)
  • Features

    • Start-stop interface for absolute transducers and magnetostrictive sensors
    • Adjustable frequency of the init pulses from 62.5 Hz to 5 kHz
    • Analog output ± 10 V, 0/4 ... 20 mA, 16 bit
    • Power supply 18 ... 30 VDC
    • Compact housing for mounting on a 35 mm top-hat rail (according to EN 60715)
    • Simple parameterization via the OS6.0 user interface
    • Serial RS232 / RS485 interface
    • Pulse inputs A, B [HTL], A, /A, B, /B [RS422, HTL]
    • SSI input DATA+, DATA-, CLOCK+, CLOCK- [RS422], 32 Bit
    • USB interface and RS232/RS485 interface for configuration and serial readout