In addition to their broad product portfolio in the areas of safety relays, digital indicators, motion controllers and signal converters, Encoder Technology can also offer customer-specific automation solutions from Motrona according to your individual requirements. With Encoder Technology, you are choosing a reliable specialist with the highest level of competence and flexibility when it comes to advice, finding solutions and short-term product deliveries from Motrona and other brands.
-
Features
- Frequency inputs A, B [HTL], A, / A, B, / B [RS422, HTL]
- 3 control inputs (hold) for PNP signals [10 ... 30 VDC]
- SSI input in the format DATA +, DATA-, CLOCK +, CLOCK- up to 32 bits
- Start-stop interface for absolute transducers and magnetostrictive sensors
- Input frequency up to 1 MHz
- 25-bit parallel output push-pull in BCD, binary or Gray code format
- Power supply 18 ... 30 VDC
- Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)
-
Features
- Pulse inputs A, B [HTL], A, /A, B, /B [RS422, HTL]
- Input frequency up to 1 MHz [RS422], 200 kHz [HTL]
- Analog output ±10 V or 0/4 ... 20 mA, 16 Bit
- Power supply 18 ... 30 VDC
- Snap-on housing for top-hat rail (according to EN 60715)
- Setup via operator software OS6.0
- Serial RS232- / RS485 interface
- SSI input DATA+, DATA-, CLOCK+, CLOCK- [RS422], 32 Bit
- Start-stop interface for absolute transducers and magnetostrictive sensors
- USB interface and RS232/RS485 interface for configuration and serial readout
-
Features
- Control input with format [HTL]
- 2 SSI inputs with format [RS422]
- Cutt-off frequency 100 kHz ... 1 MHz
- 2 encoder inputs, short-circuit-proof
- 1 SSI output with format [RS422]
- Power supply 12 ... 30 V DC
- Current consumption (unloaded) 50 mA
- Encoder supply 2 x 125mA (Vin – 2 V) short-circuit-proof
- Delay / Output / Input100 ns
- Operation temperature : 0 ... 45 °C (32 ... 113 °F)
- SSI pause time min. 25 ns
- Switching time is synchronized automatically with the next SSI break
- Cascadable for more SSI encoders
- All connections via pluggable screw terminal block
- Snap-on housing for top-hat rail (according to EN 60715)
- LEDs for indication of the input pulses
- Dimension W x H x D = 22,5 x 121 x 112 mm (8.86 x 47.64 x 44.09'')
- Plastic housing incl. plug
-
Features
- 2 x 6 control outputs für HTL / PNP signals
- Pulse inputs with format A, /A, B, /B, Z, /Z [RS422]
- Input frequency up to 1 MHz
- 2 encoder outputs, short-circuit-proof [TTL / RS422]
- Power supply 12 ... 30 VDC
- Current consumption (unloaded) 30 mA
- Encoder supply 5 ... 35 VDC (extern connect to +VAUX)
- Operation temperature: 0 ... 60 °C (32 ... 140°F)
- Latency time < 250ns
- Channel switching < 1 ms
- Open plastic housing for top-hat rail (according to EN 60715)
- LEDs for indication of the input pulses
-
Features
- 1 pulse input with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422]
- Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
- 2 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
- BUS interface for quick and easy expansion of the number of outputs
- Power supply 10 ... 30 VDC
- Signal delay time 160 ns
- Input level at RS422 / TTL (differential voltage > 0.5 V),
- Input level at HTL differential (differential voltage > 2 V),
- Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
- Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
- Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
- Dimensions W x H x D = 34 x 118 x 140 mm (1,34 x 4,65 x 5,51")
-
Features
- 1 pulse input with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422]
- Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
- 4 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
- BUS interface for quick and easy expansion of the number of outputs
- Power supply 10 ... 30 VDC
- Signal delay time 160 ns
- Input level at RS422 / TTL (differential voltage > 0.5 V),
- Input level at HTL differential (differential voltage > 2 V),
- Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
- Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
- Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
- Dimensions W x H x D = 34 x 118 x 140 mm (1,34 x 4,65 x 5,51")
-
Features
- 1 pulse input with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422]
- Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
- 8 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
- BUS interface for quick and easy expansion of the number of outputs
- Power supply 10 ... 30 VDC
- Signal delay time 160 ns
- Input level at RS422 / TTL (differential voltage > 0.5 V),
- Input level at HTL differential (differential voltage > 2 V),
- Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
- Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
- Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
- Dimensions W x H x D = 54 x 118 x 140 mm (2,13 x 4,65 x 5,51")
-
Features
- 1 pulse input with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422]
- Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
- 8 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
- BUS interface for quick and easy expansion of the number of outputs
- Power supply 10 ... 30 VDC
- Signal delay time 160 ns
- Input level at RS422 / TTL (differential voltage > 0.5 V),
- Input level at HTL differential (differential voltage > 2 V),
- Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
- Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
- Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
- Dimensions W x H x D = 54 x 118 x 140 mm (2,13 x 4,65 x 5,51")
-
Features
- 1 encoder input programmable with format A, /A, B, /B, Z, /Z [TTL / RS422] or optionally A, B, Z [HTL]
- Input frequency 750 kHz [TTL] or 300 kHz [HTL]
- 2 pulse outputs with format A, /A, B, /B, Z, /Z with individual adjustable output levels 5 V [TTL] or 10 ... 30 V [HTL]
- Power supply optionally 5 VDC or 10 ... 30 VDC
- Auxiliary voltage +5 V for encoder supply 10 ... 30 VDC
-
Features
- 2 pulse inputs with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422]
- Input frequency up to 250 kHz for asymmetrical and up to 1 MHz for symmetric signals
- 2 control inputs for HTL / PNP signals [10 ... 30 VDC]
- 2 output channels with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422], each output adjustable separately
- Power supply 12 ... 30 VDC
- Snap-on housing for top-hat rail (according to EN 60715)
-
Features
- 1 pulse input with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422]
- Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
- 4 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
- BUS interface for quick and easy expansion of the number of outputs
- Power supply 10 ... 30 VDC
- Signal delay time 160 ns
- Input level at RS422 / TTL (differential voltage > 0.5 V),
- Input level at HTL differential (differential voltage > 2 V),
- Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
- Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
- Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
- Dimensions W x H x D = 34 x 118 x 140 mm (1,34 x 4,65 x 5,51")
-
Features
- 1 pulse input with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422]
- Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
- 8 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
- BUS interface for quick and easy expansion of the number of outputs
- Power supply 10 ... 30 VDC
- Signal delay time 160 ns
- Input level at RS422 / TTL (differential voltage > 0.5 V),
- Input level at HTL differential (differential voltage > 2 V),
- Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
- Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
- Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
- Dimensions W x H x D = 54 x 118 x 140 mm (2,13 x 4,65 x 5,51")
-
Features
- 1 pulse input with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422]
- Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
- 8 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
- BUS interface for quick and easy expansion of the number of outputs
- Power supply 10 ... 30 VDC
- Signal delay time 160 ns
- Input level at RS422 / TTL (differential voltage > 0.5 V),
- Input level at HTL differential (differential voltage > 2 V),
- Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
- Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
- Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
- Dimensions W x H x D = 54 x 118 x 140 mm (2,13 x 4,65 x 5,51")
-
Features
- 2 scalable inputs with format DATA+, DATA-, CLOCK+, CLOCK- [SSI, absolute] or A, /A, B, /B [RS422, incremental]
- 4 control inputs for PNP / NPN / Namur signals [10 ... 30 VDC]
- Input frequency up to 1 MHz
- 4 fast transistor outputs with push-pull characteristics, short-circuit-proof [5 ... 30 VDC]
- Scalable 14 bit analog output ±10 V or 0/4 ... 20 mA
- 4 programmable preset values
- Power supply 24 VAC and 17 ... 40 VDC
- Compact norm panel housing
- LED display 8 digits with 10 mm height
- Display range -19999999 ... 99999999
- Serial RS232 interface
- Dimension B x H x T = 96 x 48 x 140 mm (3.78 x 1.89 x 5.51 ")
-
Features
- 2 scalable inputs with format DATA+, DATA-, CLOCK+, CLOCK- [SSI, absolute] or A, /A, B, /B [RS422, incremental]
- 4 control inputs for PNP / NPN / Namur signals [10 ... 30 VDC]
- Input frequency up to 1 MHz
- 4 fast transistor outputs with push-pull characteristics, short-circuit-proof [5 ... 30 VDC]
- Scalable 14 bit analog output ±10 V or 0/4 ... 20 mA
- 4 programmable preset values
- Power supply 24 VAC and 17 ... 40 VDC
- Compact norm panel housing
- LED display 6 digits with 15 mm height
- Display range -199999 ... 999999
- Serial RS232 interface
- Dimension B x H x T = 96 x 48 x 140 mm (3.78 x 1.89 x 5.51 ")
-
Features
- 2 scalable inputs with format DATA+, DATA-, CLOCK+, CLOCK- [SSI, absolute] or A, /A, B, /B [RS422, incremental]
- 4 control inputs for PNP / NPN / Namur signals [10 ... 30 VDC]
- Input frequency up to 1 MHz
- Scalable 14 bit analog output ±10 V or 0/4 ... 20 mA
- 4 output relays with potential free change-over contact
- 4 fast transistor outputs with push-pull characteristics, short-circuit-proof [5 ... 30 VDC]
- 4 programmable preset values
- Power supply 24 VAC and 17 ... 40 VDC
- Compact norm panel housing
- LED display 8 digits with 10 mm height
- Display range -19999999 ... 99999999
- Serial RS232 interface
- Dimension B x H x T = 96 x 96 x 140 mm (3.78 x 3.78 x 5.51 ")
-
Features
- 2 scalable inputs with format DATA+, DATA-, CLOCK+, CLOCK- [SSI, absolute] or A, /A, B, /B [RS422, incremental]
- 4 control inputs for PNP / NPN / Namur signals [10 ... 30 VDC]
- Input frequency up to 1 MHz
- Scalable 14 bit analog output ±10 V or 0/4 ... 20 mA
- 4 fast transistor outputs with push-pull characteristics, short-circuit-proof [5 ... 30 VDC]
- 4 output relays with potential free change-over contact
- 4 programmable preset values
- Power supply 24 VAC and 17 ... 40 VDC
- Compact norm panel housing
- LED display 8 digits with 10 mm height
- Display range -19999999 ... 99999999
- 2 front-panel preselections for the switching function
- Serial RS232 interface
- Dimension B x H x T = 96 x 96 x 140 mm (3.78 x 3.78 x 5.51 ")
-
Features
- 2 scalable inputs with format DATA+, DATA-, CLOCK+, CLOCK- [SSI, absolute] or A, /A, B, /B [RS422, incremental]
- 4 control inputs for PNP / NPN / Namur signals [10 ... 30 VDC]
- Input frequency up to 1 MHz
- Scalable 14 bit analog output ±10 V or 0/4 ... 20 mA
- 4 fast transistor outputs with push-pull characteristics, short-circuit-proof [5 ... 30 VDC]
- 4 output relays with potential free change-over contact
- 4 programmable preset values
- Power supply 24 VAC and 17 ... 40 VDC
- Compact norm panel housing
- LED display 8 digits with 10 mm height
- Display range -19999999 ... 99999999
- 4 front-panel preselections for the switching function
- Serial RS232 interface
- Dimension B x H x T = 96 x 96 x 140 mm (3.78 x 3.78 x 5.51 ")
-
Features
- 2 scalable inputs with format DATA+, DATA-, CLOCK+, CLOCK- [SSI, absolute] or A, /A, B, /B [RS422, incremental]
- 4 control inputs for PNP / NPN / Namur signals [10 ... 30 VDC]
- Input frequency up to 1 MHz
- Scalable 14 bit analog output ±10 V or 0/4 ... 20 mA
- 4 fast transistor outputs with push-pull characteristics, short-circuit-proof [5 ... 30 VDC]
- 4 output relays with potential free change-over contact
- 4 programmable preset values
- Power supply 24 VAC and 17 ... 40 VDC
- Compact norm panel housing
- LED display 6 digits with 15 mm height
- Display range -199999 ... 999999
- Serial RS232 interface
- Dimension B x H x T = 96 x 96 x 140 mm (3.78 x 3.78 x 5.51 ")
-
Features
- 2 scalable inputs with format DATA+, DATA-, CLOCK+, CLOCK- [SSI, absolute] or A, /A, B, /B [RS422, incremental]
- 4 control inputs for PNP / NPN / Namur signals [10 ... 30 VDC]
- Input frequency up to 1 MHz
- Scalable 14 bit analog output ±10 V or 0/4 ... 20 mA
- 4 fast transistor outputs with push-pull characteristics, short-circuit-proof [5 ... 30 VDC]
- 4 output relays with potential free change-over contact
- 4 programmable preset values
- Power supply 24 VAC and 17 ... 40 VDC
- Compact norm panel housing
- LED display 6 digits with 15 mm height
- Display range -199999 ... 999999
- Serial RS232 interface
- 2 front-panel preselections for the switching function
- Dimension B x H x T = 96 x 96 x 140 mm (3.78 x 3.78 x 5.51 ")
-
Features
- 2 scalable inputs with format DATA+, DATA-, CLOCK+, CLOCK- [SSI, absolute] or A, /A, B, /B [RS422, incremental]
- 4 control inputs for PNP / NPN / Namur signals [10 ... 30 VDC]
- Input frequency up to 1 MHz
- Scalable 14 bit analog output ±10 V or 0/4 ... 20 mA
- 4 fast transistor outputs with push-pull characteristics, short-circuit-proof [5 ... 30 VDC]
- 4 output relays with potential free change-over contact
- 4 programmable preset values
- Power supply 24 VAC and 17 ... 40 VDC
- Compact norm panel housing
- LED display 6 digits with 15 mm height
- Display range -199999 ... 999999
- Serial RS232 interface
- 4 front-panel preselections for the switching function
- Dimension B x H x T = 96 x 96 x 140 mm (3.78 x 3.78 x 5.51 ")
-
Features
- 2 scalable inputs with format DATA+, DATA-, CLOCK+, CLOCK- [SSI, absolute] or A, /A, B, /B [RS422, incremental]
- 4 control inputs for PNP / NPN / Namur signals [10 ... 30 VDC]
- Input frequency up to 1 MHz
- 4 fast transistor outputs with push-pull characteristics, short-circuit-proof [5 ... 30 VDC]
- 4 programmable preset values
- Power supply 24 VAC and 17 ... 40 VDC
- Compact norm panel housing
- LED display 8 digits with 10 mm height
- Display range -19999999 ... 99999999
- Serial RS232 interface
- Dimension B x H x T = 96 x 48 x 140 mm (3.78 x 1.89 x 5.51 ")
-
Features
- 2 scalable inputs with format DATA+, DATA-, CLOCK+, CLOCK- [SSI, absolute] or A, /A, B, /B [RS422, incremental]
- 4 control inputs for PNP / NPN / Namur signals [10 ... 30 VDC]
- Input frequency up to 1 MHz
- 4 fast transistor outputs with push-pull characteristics, short-circuit-proof [5 ... 30 VDC]
- 4 programmable preset values
- Power supply 24 VAC and 17 ... 40 VDC
- Compact norm panel housing
- LED display 6 digits with 15 mm height
- Display range -199999 ... 999999
- Serial RS232 interface
- Dimension B x H x T = 96 x 48 x 140 mm (3.78 x 1.89 x 5.51 ")