• Features

    • SSI input with format DATA+, DATA-, CLOCK+, CLOCK-
    • SSI clock frequencies up to 1 MHz
    • Master or Slave operation
    • For single-turn and multi-turn encoders with 10 … 32 Bit
    • 3 control inputs for HTL / PNP signals
    • Power supply 18 ... 30 VDC
    • 24 V auxiliary output for encoder supply
    • 3.78 x 1.89-inch norm panel housing and IP65 protection
    • Bright and high-contrast display with event-dependent color variations
    • Emulation of a 7-segment display inclusively icons and units
    • Intuitive and easy parameterization by plain text and touchscreen
    • Operating modes such as scaling and bit blanking
    • Linearization with 24 control points

    Options

    • Option AC: Power supply 115 ... 230 VAC
    • Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
    • Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
    • Option CO: 4 control outputs, serial RS232 interface
    • Option CR: 4 control outputs, serial RS485 interface
    • Option RL: 2 relay outputsOptions can be combined.
  • Features

    • SSI input with format DATA+, DATA-, CLOCK+, CLOCK-
    • SSI clock frequencies up to 1 MHz
    • Master or Slave operation
    • For single-turn and multi-turn encoders with 10 … 32 Bit
    • 3 control inputs for HTL / PNP signals
    • Power supply 18 ... 30 VDC
    • 5 / 24 V auxiliary output for encoder supply
    • 3.78 x 1.89-inch norm panel housing and IP65 protection
    • Bright and high-contrast display with event-dependent color variations
    • Emulation of a 7-segment display inclusively icons and units
    • Intuitive and easy parameterization by plain text and touchscreen
    • Operating modes such as scaling, bit blanking and wire break monitoring
    • Linearization with 24 control points

    Options

    • Option AC: Power supply 115 ... 230 VAC
    • Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
    • Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
    • Option CO: 4 control outputs, serial RS232 interface
    • Option CR: 4 control outputs, serial RS485 interface
    • Option RL: 2 relay outputs
    Options can be combined
  • Features

    • 4 independent input channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422], also possible for single-channel
    • 4 output channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422]
    • Maximum input frequency 1 MHz
    • Very short conversion time < 300 ns
    • Optical wavelength 1300 nm
    • Transmission distance up to 3000 meters
    • Power supply 5 VDC (for LW213)
    • Power supply 10 ... 30 VDC (for LW213-1, LW213-2, LW213-3)
    • Snap-on housing for top-hat rail (according to EN 60715)
    • Pre-configured optical fibres are available
  • Features

    • 4 independent input channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422], also possible for single channel
    • 4 output channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422]
    • Maximum input frequency 1 MHz
    • Very short conversion time < 300 ns
    • Optical wavelength 1300 nm
    • Transmission distances up to 3000 meters
    • Power supply 5 VDC (for LW214)
    • Power supply 10 ... 30 VDC (for LW214-1, LW214-2)
    • Snap-on housing for top-hat rail (according to EN 60715)
    • Pre-configured optical fibers are available
  • Features

    • 4 independent input channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422], also possible for single channel
    • 4 output channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422]
    • Maximum input frequency 1 MHz
    • Very short conversion time < 300 ns
    • Optical wavelength 850 nm
    • Transmission distance up to 2000 meters
    • Power supply 5 VDC (for LW215)
    • Power supply 10 ... 30 VDC (for LW215-1, LW215-2, LW216-3)
    • Snap-on housing for top-hat rail (according to EN 60715)
    • Pre-configured optical fibers are available
  • Features

    • 4 independent input channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422], also possible for single channel
    • 4 output channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422]
    • Maximum input frequency 1 MHz
    • Very short conversion time < 300 ns
    • Optical wavelength 850 nm
    • Transmission distance up to 2000 meters
    • Power supply 5 VDC (for LW216)
    • Power supply 10 ... 30 VDC (for LW216-1, LW216-2)
    • Snap-on housing for top-hat rail (according to EN 60715)
    • Pre-configured optical fibers are available
  • Features

    • 1 SSI input / output channel [RS422] with format DATA+, DATA-, CLOCK+, CLOCK-
    • 1 Error input (LW217) resp. 1 open-drain-output (LW218)
    • Maximum input frequency 1 MHz
    • Very short conversion time < 300 nsec.
    • Optical wavelength 850 nm
    • Transmission distance up to 2000 meters
    • Power supply 5 VDC (for LW217)
    • Power supply 10 ... 30 VDC (for LW217-1)
    • Free adjustable SSI resolution from 1 ... 99 bit
    • Snap-on housing for top-hat rail (according to EN 60715)
    • Pre-configured optical fibres are available
  • Features

    • 1 SSI input / output channel [RS422] with format DATA+, DATA-, CLOCK+, CLOCK-
    • 1 open-drain-output (LW218)
    • Maximum input frequency 1 MHz
    • Very short conversion time < 300 ns
    • Optical wavelength 1300 nm
    • Transmission distance up to 2000 meters
    • Power supply 5 VDC (for LW218)
    • Power supply 10 ... 30 VDC (for LW218-1)
    • Free adjustable SSI resolution from 1 ... 99 bit
    • Snap-on housing for top-hat rail (according to EN 60715)
    • Glass fibre cables are available ready-assembled
  • Features

    • Pulse input with format A, B, 90° [HTL], single channel as an option
    • HTL input for encoder and sensors with NPN / PNP or NAMUR switching characteristics
    • Input frequency up to 250 kHz
    • 3 control inputs for HTL / PNP signals
    • Power supply 18 ... 30 VDC
    • 24 V auxiliary output for encoder supply
    • 3.78 x 1.89-inch norm panel housing and IP65 protection
    • Bright and high-contrast display with event-dependent colour variations
    • Emulation of a 7-segment display inclusively icons and units
    • Intuitive and easy parameterization by plain text and touchscreen
    • Multi-function device for use as speedometer/tachometer, pulse counter/position indicator, number counter and total counter
    • Operating modes such as scaling, average filter, start-up suppression
    • Linearization with 24 control points

    Options

    • Option AC: Power supply 115 ... 230 VAC
    • Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
    • Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
    • Option CO: 4 control outputs, serial RS232 interface
    • Option CR: 4 control outputs, serial RS485 interface
    • Option RL: 2 relay outputs
    Options can be combined.
  • Features

    • Incremental input with format A, /A, B, /B
    • Differential, single-ended HTL / RS422
    • Input frequency up to 1 MHz
    • 3 control inputs for HTL / PNP signals
    • Power supply 18 ... 30 VDC
    • 24 V auxiliary output for encoder supply
    • 3.78 x 1.89-inch norm panel housing and IP65 protection
    • Bright and high-contrast display with event-dependent colour variations
    • Emulation of a 7-segment display inclusively icons and units
    • Intuitive and easy parameterization by plain text and touchscreen
    • Multi-function device for use as speedometer/tachometer, pulse counter/position indicator, number counter and total counter
    • Operating modes such as scaling, average filter, start-up suppression
    • Linearization with 24 control points

    Options

    • Option AC: Power supply 115 ... 230 VAC
    • Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
    • Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
    • Option CO: 4 control outputs, serial RS232 interface
    • Option CR: 4 control outputs, serial RS485 interface
    • Option RL: 2 relay outputs
    Options can be combined.

Title