• Features

    • Type: Non-contact magnetic linear encoder (measures displacement without physical contact)
    • Measuring length: Up to 50 meters
    • Function: Converts linear movements of machine components into electrical signals with information about:
      • Value: Distance travelled
      • Direction: Forward or backward movement
    • Durability: Designed for harsh industrial environments and resistant to various contaminants and physical impacts.
    • Components:
      • Metal-based magnetic band (MP): Stores the encoded information
      • Reading head: Detects the magnetic field variations on the band and converts them into electrical signals
      • Profile rail (PS) with protective band: Provides mounting and protects the reading head
  • Features

    • Type: Photoelectric linear displacement measuring device (measures changes in position)
    • Measuring length: Up to 2.040 mm
    • Grating period: Two options available: ±20 µm or ±40 µm (determines the smallest detectable movement)
    • Accuracy: Up to ±3 µm (indicates the encoder's closeness to the actual displacement)
  • Features

    • Measuring length: Up to 3.240 mm
    • Accuracy: Up to ±5 µm within any meter of its measuring length
    • Grating periods: Available in two options: ±20 µm and ±40 µm
  • Features

    • Similar to the L18 series: Shares most functionalities and specifications with the L18 series encoders.
    • Different housing fixation: Requires distinct mounting methods compared to the L18 series.
    • Improved thermal behaviour: More stable performance under different temperatures.
  • Features

    • Type: Photoelectric modular linear encoder
    • Measuring length:
      • Up to 20,000 mm (20 meters)
      • Can be even longer with special order
    • Accuracy: Up to ±3 µm
     
  • Features

    • Type: Incremental linear displacement measuring device (measures changes in position)
    • Measuring length: Up to 3.240 mm
    • Accuracy: Up to ±3 µm within any meter of its measuring length (accuracy scales with length)
    • Vibration resistance: More resistant to vibrations than the L18 series encoders
  • Features

    • Similar to the L35 series: Shares most functionalities and specifications with the L35 series encoders.
    • Different mounting parameters: Requires distinct mounting methods compared to the L35 series.
    • Measuring length: Up to 3.240 mm.
    • Enhanced vibration resistance: More resistant to vibrations than the L18 series encoders, making it suitable for applications with higher vibration levels.
     
  • Features

    • Type: Incremental encoder
    • Thermal behaviour: Reproducible, indicating stability under temperature changes
    • Reading head: Reversible for flexibility in installation
    • Measuring length: Up to 3.240 mm
    • Accuracy: Up to ±3 µm within the measuring length
  • Features

    • Type: Incremental encoder
    • Measuring length: 3.240 mm to 30.040 mm
    • Grating period: 40 µm
    • Accuracy: Up to ±10 µm within the measuring length
  • Features

    • Type: Photoelectric absolute linear encoder (measures absolute position)
    • Measuring length: Up to 3.240 mm (customizable)
    • Interface: SSI or BiSS serial interface for digital communication
    • Accuracy: Up to ±1 µm high accuracy
    • Optional incremental track: Provides 1Vpp incremental signal for applications requiring both absolute and incremental position data.
  • Features

    • Magnetic absolute linear encoder
    • MK has a measuring length of up to 50.000 mm
    • Accuracy can reach up to ±35 μm.
    • Encoder has two versions of serial interface - SSI or BiSS C
    • Optionally it can have 2 analog sinusoidal signals with phase shift 90°C and amplitude approx. 1Vpp.
  • Features

    • Measuring length: Up to 50,000 mm (50 meters)
    • Accuracy: Up to ±25 micrometres (μm)
    • Customizable: Other parameters can be modified to meet specific needs
  • Features

    • Converts the movement of key machine parts into electrical signals.
    • Designed for harsh industrial environments and resistant to various physical and environmental factors.
    • Magnetic band length can reach up to 50 meters.
    • Allows for either user-defined reference marks or external zero signal actuator.
    • LED on the reading head confirms reference mark detection.
    • Compressed air can be used to clean the rail surface, improving accuracy.
    • Two output signal options:
      • PCMT-F: Square-wave with built-in interpolation electronics.
      • PCMT-AV: Sinusoidal signal requiring external interpolation.
  • Features

    • Single channel pulse input [HTL]
    • Input frequency up to 20 kHz
    • Programmable input filter for mechanical input contacts
    • Power supply 24 VDC
    • Miniature norm panel housing
    • 6 digits LED display with 8 mm height
    • Display range  -199999 ... 999999
    • Dimension B x H x T = 48 x 24 x 59 mm (1.89 x 0.94 x 2.32 ")
  • Features

    • Pulse input with format A, B, 90° [HTL], single channel as an option
    • HTL inputs for encoder and sensors with NPN / PNP or NAMUR switching characteristics
    • Input frequency up to 250 kHz
    • 3 control inputs for HTL / PNP signals
    • Power supply 18 ... 30 VDC
    • 24 V auxiliary output for encoder supply
    • 3.78 x 1.89-inch norm panel housing and IP65 protection
    • Bright and high-contrast display with event-dependent color variations
    • Emulation of a 7-segment display inclusively icons and units
    • Intuitive and easy parameterization by plain text and touchscreen
    • Multi-functional device for speed, position, timer, counter or velocity application
    • Operating modes such as scaling, average filter, start-up suppression
    • Linearization with 24 control points

    Options

    • Option AC: Power supply 115 ... 230 VAC
    • Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
    • Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
    • Option CO: 4 control outputs, serial RS232 interface
    • Option CR: 4 control outputs, serial RS485 interface
    • Option RL: 2 relay outputs
    Options can be combined.
  • Features

    • 2 Incremental inputs with format A, /A, B, /B
    • Differential, single-ended HTL / RS422
    • Input frequency up to 1 MHz
    • Power supply 18 ... 30 VDC
    • 5 / 24 VDC auxiliary output for encoder supply
    • 3.78 x 1.89-inch norm panel housing and IP65 protection
    • Bright and high-contrast display with event-dependent color variations
    • Emulation of a 7-segment display inclusively icons and units
    • Intuitive and easy parameterization by plain text and touchscreen
    • Multi-functional device for speed, process time, timer, counter or velocity application
    • Operating modes such as scaling, average filter, start-up suppression
    • Linearization with 24 control points

    Options

    • Option AC: Power supply 115 ... 230 VAC
    • Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
    • Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
    • Option CO: 4 control outputs, serial RS232 interface
    • Option CR: 4 control outputs, serial RS485 interface
    • Option RL: 2 relay outputsOptions can be combined.

Title

Go to Top