• Features

    • Individual scalable process or speed indicator
    • Dual channel frequency indicator for visualization of the encoder frequency
    • Display of alarm and error codes
    • Touch screen with intuitive menu guidance
    • 1.54" OLED Display (128 x 64 Pixel)
    • Dimension: 50 x 80 x 15 mm (1,97 x 3,15 x  0,59")
  • Features

    • Simple parameterization of motrona safety devices
    • Editing, saving and loading of parameters
    • Individual scalable process or speed indicator
    • Dual channel frequency indicator for visualization of the encoder frequency
    • Touch screen with intuitive menu guidance
    • 1.54" OLED Display (128 x 64 Pixel)
    • Dimension: 50 x 80 x 15 mm (1,97 x 3,15 x  0,59")
  • Features

    • SIL3 and PLe certification
    • Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
    • 2 encoder inputs with format SIN+, SIN-, COS+, COS- [1 Vss]
    • 2 pulse inputs with format A, /A, B, /B [RS422]
    • 2 pulse- or control inputs with format A, B, 90° [HTL / PNP] (for rotary encoder, proximity switches or commands)
    • Input frequency up to 500 kHz
    • Forced-guided redundant output relay (NO)
    • 4 control outputs with push-pull characteristic, short-circuit-proof, [HTL], each inverse and redundant
    • Safety related 14 bit analog output for 4 ... 20 mA (scalable)
    • With signal splitter
    • Power supply 18 ... 30 V
    • Compact housing for 35 mm mounting top hat rail
    • (according to EN 60715)
    • Setup via USB port by operator software or plug-in display and programming unit BG230 (accessories)
  • Features

    • SIL3 and PLe certification
    • Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
    • 2 encoder inputs with format SIN+, SIN-, COS+, COS- [1 Vss]
    • 2 pulse inputs with format A, /A, B, /B [RS422]
    • 2 pulse- or control inputs with format A, B, 90° [HTL / PNP] (for rotary encoder, proximity switches or commands)
    • Input frequency up to 500 kHz
    • Forced-guided redundant output relay (NO)
    • 4 control outputs with push-pull characteristics, short-circuit-proof, [HTL], each inverse and redundant
    • Safety-related 14-bit analogue output for 4 ... 20 mA (scalable)
    • Power supply 18 ... 30 V
    • Compact housing for 35 mm mounting top-hat rail (according to EN 60715)
    • Setup via USB port by operator software or plug-in display and programming unit BG230 (accessories)
  • Features

    • SIL3 and PLe certification
    • Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
    • 2 encoder input with format SIN+, SIN-, COS+, COS- [1 Vss]
    • 2 pulse- or control inputs with format A, B, 90° [HTL / PNP] (for rotary encoder, proximity switches or commands)
    • Input frequency up to 500 kHz
    • Forced-guided redundant output relay (NO)
    • 4 control outputs with push-pull characteristic, short-circuit-proof, [HTL], each inverse and redundant
    • Safety-related 14 bit analogue output for 4 ... 20 mA (scalable)
    • With signal splitter
    • Power supply 18 ... 30 V
    • Compact housing for 35 mm mounting top hat rail (according to EN 60715)
    • Setup via USB port by operator software or plug-in display and programming unit BG230 (accessories)
  • Features

    • SIL3 and PLe certification
    • Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
    • 2 encoder input with format SIN+, SIN-, COS+, COS- [1 Vss]
    • 2 pulse inputs with format A, /A, B, /B [RS422]
    • 2 pulse- or control inputs with format A, B, 90° [HTL / PNP] (for rotary encoder, proximity switches or commands)
    • Input frequency up to 500 kHz
    • Forced-guided redundant output relay (NO)
    • 4 control outputs with push-pull characteristic, short-circuit-proof, [HTL], each inverse and redundant
    • Safety related 14 bit analog output for 4 ... 20 mA (scalable)
    • Power supply 18 ... 30 V
    • Compact housing for 35 mm mounting top hat rail (according to EN 60715)
    • Setup via USB port by operator software or plug-in display and programming unit BG230 (accessories)
  • Features

    • SIL3 and PLe certification
    • Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
    • 2 incremental encoder inputs with format A, /A, B, /B, Z, /Z [HTL differencial, HTL single ended, RS422]
    • 8 control inputs [HTL / PNP]
    • Input frequency up to 500 kHz
    • 2 relay outputs 5... 250 VAC / VDC (NO)
    • 4 x 2 control outputs with push-pull characteristic, short-circuit-proof, [HTL], antivalent or equivalent redundant or simply used
    • Safety related 14 bit analog output for 4 ... 20 mA (scalable)
    • Signal splitter
    • Power supply 18 ... 30 V
    • Wire monitoring of the sensor signals
    • Compact housing for 35 mm mounting top hat rail (according to EN 60715)
    • USB interface in combination with the user interface OS6.0 for the parameterization of the safety speed monitor
    • BG200 operator panel for easy parameterization and display (optional)
  • Features

    • SIL3 and PLe certification (depends on the used encoder/sensor arrangement)
    • Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
    • 1 incremental encoder input with format A, /A, B, /B, Z, /Z [HTL differencial, RS422]
    • 8 control inputs [HTL / PNP]
    • Input frequency up to 500 kHz
    • 2 relay outputs 5... 250 VAC / VDC (NO)
    • 4 x 2 control outputs with push-pull characteristic, short-circuit-proof, [HTL], antivalent or equivalent redundant or simply used
    • Safety related 14 bit analog output for 4 ... 20 mA (scalable)
    • Signal splitter
    • Power supply 18 ... 30 V
    • Wire monitoring of the sensor signals
    • Compact housing for 35 mm mounting top hat rail (according to EN 60715)
    • USB interface in combination with the user interface OS6.0 for the parameterization of the safety speed monitor
    • BG200 operator panel for easy parameterization and display (optional)
  • Features

    • Encoder input with format SIN+, SIN-, COS+, COS-, REF+, REF- [1 Vss]
    • Control input „Error Release“ for PNP signals [10 ... 30 VDC]
    • Input frequency up to 400 kHz
    • Pulse output with format A, /A, B, /B, Z, /Z [RS422] or with format A, B, 90° [HTL]
    • Output frequency up to 4 MHz [RS422]
    • Control output „Error“ with push-pull characteristic, short-circuit-proof, [5 ... 30 VDC]
    • Power supply 18 ... 30 VDC
    • Snap-on housing for top-hat rail (according to EN 60715)
    • Adjustable multiplier for interpolation rates from 1:5 to 1:50
    • Adjustable divider 1:1 – 1:255 to reduce the output frequency
  • Features

    • 1 encoder input with format SIN+, SIN-, COS+, COS-, REF+, REF- [1 Vss]
    • Maximum sinus input frequency 500 kHz with max. 200 ns conversion time
    • 2 signal outputs with format SIN+, SIN-, COS+, COS-, REF+, REF- [1 Vss]
    • 2 pulse outputs with format A, /A, B, /B, Z, /Z [RS422, TTL, HTL]
    • Power supply 17 ... 30 VDC
    • Snap-on housing for top-hat rail (according to EN 60715)
  • Features

    • 1 encoder input with format SIN+, SIN-, COS+, COS-, REF+, REF- [1 Vss]
    • Maximum sinus input frequency 500 kHz with max. 200 ns conversion time
    • 4 signal outputs with format SIN+, SIN-, COS+, COS-, REF+, REF- [1 Vss]
    • Power supply 17 ... 30 VDC
    • Snap-on housing for top-hat rail (according to EN 60715)

Title