• Features

    • Strain gauge input, 6-wire connection
    • Input pt100 and thermocouples (J and K)
    • 3 control inputs for HTL / PNP signals
    • Power supply 18 ... 30 VDC
    • Adjustable bridge voltage 3 VDC to 10 VDC
    • 1 … 10 mV sensitivity
    • Standard installation housing with 96 x 48 mm and protection class IP65
    • Bright and high-contrast graphic display with event-dependent color variants
    • Emulation of a 7-segment display with symbols and units
    • Intuitive and simple parameterization through plain text and touchscreen
    • Numerous functions such as tare, filter, averaging
    • Linearization with 24 support points

    Options

    • Option AC: Power supply 115 ... 230 VAC
    • Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
    • Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
    • Option CO: 4 control outputs, serial RS232 interface
    • Option CR: 4 control outputs, serial RS485 interface
    • Option RL: 2 relay outputs
    • Option IO: IO-Link Device V1.1
    Options can be combined.
  • Features

    • Start-stop interface for absolute transducers and magnetostrictive sensors
    • SSI input in the format DATA +, DATA-, CLOCK +, CLOCK- up to 32 bits
    • 3 control inputs (hold) for PNP signals [10 ... 30 VDC]
    • Pulse inputs A, B [HTL], A, / A, B, / B [RS422, HTL]
    • Input frequency up to 1 MHz
    • 25-bit parallel output push-pull in BCD, binary or Gray code format
    • Power supply 18 ... 30 VDC
    • Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)
  • Features

    • Start-stop interface for absolute transducers and magnetostrictive sensors
    • Adjustable frequency of the init pulses from 62.5 Hz to 5 kHz
    • Analog output ± 10 V, 0/4 ... 20 mA, 16 bit
    • Power supply 18 ... 30 VDC
    • Compact housing for mounting on a 35 mm top-hat rail (according to EN 60715)
    • Simple parameterization via the OS6.0 user interface
    • Serial RS232 / RS485 interface
    • Pulse inputs A, B [HTL], A, /A, B, /B [RS422, HTL]
    • SSI input DATA+, DATA-, CLOCK+, CLOCK- [RS422], 32 Bit
    • USB interface and RS232/RS485 interface for configuration and serial readout

Title

Go to Top