• Features

    • 6-wire connection for one strain gauge full bridge sensor
    • 4 control inputs [HTL/PNP]
    • 1 analog output ±10 V, 0/4 ... 20 mA, 16 bit
    • 4 control outputs for signalling different operation states
    • Power supply 18 ... 30 VDC
    • Functions for scaling and linking the sensor signals (e.g. A+B, A-B, ...)
    • Adjustable bridge voltage per sensor from 3 VDC ... 10 VDC
    • Sensitivity of the sensor inputs 1 ... 10 mV
    • Transmission of the sensor data via RS485
    • Programming via USB and the user interface OS (freeware)
    • Protection class IP20
    • Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)
  • Features

    • 6-wire connection for two independent strain gauge full bridge sensors
    • 4 control inputs [HTL/PNP]
    • 2 independent analog outputs ±10 V, 0/4 ... 20 mA, 16 bit
    • 4 control outputs for signalling different operation states
    • Power supply 18 ... 30 VDC
    • Functions for scaling and linking the sensor signals (e.g. A+B, A-B, ...)
    • Adjustable bridge voltage per sensor from 3 VDC ... 10 VDC
    • Sensitivity of the sensor inputs 1 ... 10 mV
    • Transmission of the sensor data via RS485
    • Programming via USB and the user interface OS (freeware)
    • Protection class IP20
    • Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)
  • Features

    • Strain gauge input, 6-wire connection
    • Input pt100 and thermocouples (J and K)
    • 3 control inputs for HTL / PNP signals
    • Power supply 18 ... 30 VDC
    • Adjustable bridge voltage 3 VDC to 10 VDC
    • 1 … 10 mV sensitivity
    • Standard installation housing with 96 x 48 mm and protection class IP65
    • Bright and high-contrast graphic display with event-dependent color variants
    • Emulation of a 7-segment display with symbols and units
    • Intuitive and simple parameterization through plain text and touchscreen
    • Numerous functions such as tare, filter, averaging
    • Linearization with 24 support points

    Options

    • Option AC: Power supply 115 ... 230 VAC
    • Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
    • Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
    • Option CO: 4 control outputs, serial RS232 interface
    • Option CR: 4 control outputs, serial RS485 interface
    • Option RL: 2 relay outputs
    • Option IO: IO-Link Device V1.1
    Options can be combined.
  • Features

    • 1 Strain gauge input
    • 3 VDC and 10 VDC bridge voltage per sensor connection
    • 1 … 10 mV sensitivity
    • optionally 3 control inputs for PNP signals [10 ... 30 VDC]
    • IO link interface
    • Power supply 12 ... 30 VDC
    • Compact housing for mounting on 35 mm DIN rail (according to EN 60715)

Title