• Features

    • Individual scalable process or speed indicator
    • Dual channel frequency indicator for visualization of the encoder frequency
    • Display of alarm and error codes
    • Touch screen with intuitive menu guidance
    • 1.54" OLED Display (128 x 64 Pixel)
    • Dimension: 50 x 80 x 15 mm (1,97 x 3,15 x  0,59")
  • Features

    • Simple parameterization of motrona safety devices
    • Editing, saving and loading of parameters
    • Individual scalable process or speed indicator
    • Dual channel frequency indicator for visualization of the encoder frequency
    • Touch screen with intuitive menu guidance
    • 1.54" OLED Display (128 x 64 Pixel)
    • Dimension: 50 x 80 x 15 mm (1,97 x 3,15 x  0,59")
  • Features

    • SIL3 and PLe certification
    • Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
    • 2 encoder inputs with format SIN+, SIN-, COS+, COS- [1 Vss]
    • 2 pulse inputs with format A, /A, B, /B [RS422]
    • 2 pulse- or control inputs with format A, B, 90° [HTL / PNP] (for rotary encoder, proximity switches or commands)
    • Input frequency up to 500 kHz
    • Forced-guided redundant output relay (NO)
    • 4 control outputs with push-pull characteristic, short-circuit-proof, [HTL], each inverse and redundant
    • Safety related 14 bit analog output for 4 ... 20 mA (scalable)
    • With signal splitter
    • Power supply 18 ... 30 V
    • Compact housing for 35 mm mounting top hat rail
    • (according to EN 60715)
    • Setup via USB port by operator software or plug-in display and programming unit BG230 (accessories)
  • Features

    • SIL3 and PLe certification
    • Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
    • 2 encoder inputs with format SIN+, SIN-, COS+, COS- [1 Vss]
    • 2 pulse inputs with format A, /A, B, /B [RS422]
    • 2 pulse- or control inputs with format A, B, 90° [HTL / PNP] (for rotary encoder, proximity switches or commands)
    • Input frequency up to 500 kHz
    • Forced-guided redundant output relay (NO)
    • 4 control outputs with push-pull characteristics, short-circuit-proof, [HTL], each inverse and redundant
    • Safety-related 14-bit analogue output for 4 ... 20 mA (scalable)
    • Power supply 18 ... 30 V
    • Compact housing for 35 mm mounting top-hat rail (according to EN 60715)
    • Setup via USB port by operator software or plug-in display and programming unit BG230 (accessories)
  • Features

    • SIL3 and PLe certification
    • Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
    • 2 encoder input with format SIN+, SIN-, COS+, COS- [1 Vss]
    • 2 pulse- or control inputs with format A, B, 90° [HTL / PNP] (for rotary encoder, proximity switches or commands)
    • Input frequency up to 500 kHz
    • Forced-guided redundant output relay (NO)
    • 4 control outputs with push-pull characteristic, short-circuit-proof, [HTL], each inverse and redundant
    • Safety-related 14 bit analogue output for 4 ... 20 mA (scalable)
    • With signal splitter
    • Power supply 18 ... 30 V
    • Compact housing for 35 mm mounting top hat rail (according to EN 60715)
    • Setup via USB port by operator software or plug-in display and programming unit BG230 (accessories)
  • Features

    • SIL3 and PLe certification
    • Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
    • 2 encoder input with format SIN+, SIN-, COS+, COS- [1 Vss]
    • 2 pulse inputs with format A, /A, B, /B [RS422]
    • 2 pulse- or control inputs with format A, B, 90° [HTL / PNP] (for rotary encoder, proximity switches or commands)
    • Input frequency up to 500 kHz
    • Forced-guided redundant output relay (NO)
    • 4 control outputs with push-pull characteristic, short-circuit-proof, [HTL], each inverse and redundant
    • Safety related 14 bit analog output for 4 ... 20 mA (scalable)
    • Power supply 18 ... 30 V
    • Compact housing for 35 mm mounting top hat rail (according to EN 60715)
    • Setup via USB port by operator software or plug-in display and programming unit BG230 (accessories)
  • Features

    • SIL3 and PLe certification
    • Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
    • 2 incremental encoder inputs with format A, /A, B, /B, Z, /Z [HTL differencial, HTL single ended, RS422]
    • 8 control inputs [HTL / PNP]
    • Input frequency up to 500 kHz
    • 2 relay outputs 5... 250 VAC / VDC (NO)
    • 4 x 2 control outputs with push-pull characteristic, short-circuit-proof, [HTL], antivalent or equivalent redundant or simply used
    • Safety related 14 bit analog output for 4 ... 20 mA (scalable)
    • Signal splitter
    • Power supply 18 ... 30 V
    • Wire monitoring of the sensor signals
    • Compact housing for 35 mm mounting top hat rail (according to EN 60715)
    • USB interface in combination with the user interface OS6.0 for the parameterization of the safety speed monitor
    • BG200 operator panel for easy parameterization and display (optional)
  • Features

    • SIL3 and PLe certification (depends on the used encoder/sensor arrangement)
    • Safety functions equivalent to EN 61800-5-2 (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
    • 1 incremental encoder input with format A, /A, B, /B, Z, /Z [HTL differencial, RS422]
    • 8 control inputs [HTL / PNP]
    • Input frequency up to 500 kHz
    • 2 relay outputs 5... 250 VAC / VDC (NO)
    • 4 x 2 control outputs with push-pull characteristic, short-circuit-proof, [HTL], antivalent or equivalent redundant or simply used
    • Safety related 14 bit analog output for 4 ... 20 mA (scalable)
    • Signal splitter
    • Power supply 18 ... 30 V
    • Wire monitoring of the sensor signals
    • Compact housing for 35 mm mounting top hat rail (according to EN 60715)
    • USB interface in combination with the user interface OS6.0 for the parameterization of the safety speed monitor
    • BG200 operator panel for easy parameterization and display (optional)
  • Features

    • 4 independent input channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422], also possible for single-channel
    • 4 output channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422]
    • Maximum input frequency 1 MHz
    • Very short conversion time < 300 ns
    • Optical wavelength 1300 nm
    • Transmission distance up to 3000 meters
    • Power supply 5 VDC (for LW213)
    • Power supply 10 ... 30 VDC (for LW213-1, LW213-2, LW213-3)
    • Snap-on housing for top-hat rail (according to EN 60715)
    • Pre-configured optical fibres are available
  • Features

    • 4 independent input channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422], also possible for single channel
    • 4 output channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422]
    • Maximum input frequency 1 MHz
    • Very short conversion time < 300 ns
    • Optical wavelength 1300 nm
    • Transmission distances up to 3000 meters
    • Power supply 5 VDC (for LW214)
    • Power supply 10 ... 30 VDC (for LW214-1, LW214-2)
    • Snap-on housing for top-hat rail (according to EN 60715)
    • Pre-configured optical fibers are available
  • Features

    • 4 independent input channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422], also possible for single channel
    • 4 output channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422]
    • Maximum input frequency 1 MHz
    • Very short conversion time < 300 ns
    • Optical wavelength 850 nm
    • Transmission distance up to 2000 meters
    • Power supply 5 VDC (for LW215)
    • Power supply 10 ... 30 VDC (for LW215-1, LW215-2, LW216-3)
    • Snap-on housing for top-hat rail (according to EN 60715)
    • Pre-configured optical fibers are available
  • Features

    • 4 independent input channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422], also possible for single channel
    • 4 output channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422]
    • Maximum input frequency 1 MHz
    • Very short conversion time < 300 ns
    • Optical wavelength 850 nm
    • Transmission distance up to 2000 meters
    • Power supply 5 VDC (for LW216)
    • Power supply 10 ... 30 VDC (for LW216-1, LW216-2)
    • Snap-on housing for top-hat rail (according to EN 60715)
    • Pre-configured optical fibers are available
  • Features

    • 1 SSI input / output channel [RS422] with format DATA+, DATA-, CLOCK+, CLOCK-
    • 1 Error input (LW217) resp. 1 open-drain-output (LW218)
    • Maximum input frequency 1 MHz
    • Very short conversion time < 300 nsec.
    • Optical wavelength 850 nm
    • Transmission distance up to 2000 meters
    • Power supply 5 VDC (for LW217)
    • Power supply 10 ... 30 VDC (for LW217-1)
    • Free adjustable SSI resolution from 1 ... 99 bit
    • Snap-on housing for top-hat rail (according to EN 60715)
    • Pre-configured optical fibres are available
  • Features

    • 1 SSI input / output channel [RS422] with format DATA+, DATA-, CLOCK+, CLOCK-
    • 1 open-drain-output (LW218)
    • Maximum input frequency 1 MHz
    • Very short conversion time < 300 ns
    • Optical wavelength 1300 nm
    • Transmission distance up to 2000 meters
    • Power supply 5 VDC (for LW218)
    • Power supply 10 ... 30 VDC (for LW218-1)
    • Free adjustable SSI resolution from 1 ... 99 bit
    • Snap-on housing for top-hat rail (according to EN 60715)
    • Glass fibre cables are available ready-assembled