• Features

    • 2 pulse inputs with format A, B, 90° [HTL] or A, /A, B, /B [RS422]
    • 4 control inputs for HTL / PNP / NPN / Namur signals [10 ... 30 VDC]
    • Input frequency up to 300 kHz
    • 4 fast transistor outputs, push-pull, short-circuit-proof [5 … 30 VDC]
    • 1 scalable 14-bit analog output (±10 V or 0/4 … 20 mA)
    • Loop time approx. 250 µs
    • Power supply 24 VAC and 17 … 40 VDC
    • Compact norm panel housing (according to EN 60715)
    • Top hat rail mounting by using SM300 support brackets (option)
    • Setup via keys or via PC by serial RS232 interface
    • PROFIBUS connection via Motrona gateway PB251
  • Features

    • 2 pulse inputs with format A, B, 90° [HTL] or A, /A, B, /B [RS422]
    • 4 control inputs for HTL / PNP / NPN / Namur signals [10 ... 30 VDC]
    • Input frequency up to 300 kHz
    • 4 fast transistor outputs, push-pull, short-circuit-proof [5 … 30 VDC]
    • 4 potential-free changeover relay outputs
    • 1 scalable 14-bit analog output (±10 V or 0/4 … 20 mA)
    • Loop time approx. 250 µs
    • Power supply 24 VAC and 17 … 40 VDC
    • Compact norm panel housing (according to EN 60715)
    • Top hat rail mounting by using SM600 support brackets (option)
    • Setup via keys or via PC by serial RS232 interface
    • PROFIBUS connection via Motrona gateway PB251
  • Features

    • MC700 is a universal motion controller for 1 to 4 axes, which can be assigned any motion control functions by loading firmware. Together with the firmware BY701 (see firmware), this controller offers excellent synchronous functions for 1 - 4 axes.
    • The firmware offers all conceivable possibilities for the synchronization of drives, including the influence of phase position and the relative position between the drives and numerous index and print mark functions.
    • Optionally, a "physical master" or the built-in "virtual master axis" with programmable speeds and ramps can be used as the master drive.
    • The number of successive axes can be extended arbitrarily via a cascading output.
    • MC700 controllers can be operated via an external control terminal, serial interface or optional via CANBUS (MC700/CI). PC operator software is included.
    • PROFIBUS connection possible via gateway PB251 (see accessories)
  • Features

    • Strain gauge input, 6-wire connection
    • Input pt100 and thermocouples (J and K)
    • 3 control inputs for HTL / PNP signals
    • Power supply 18 ... 30 VDC
    • Adjustable bridge voltage 3 VDC to 10 VDC
    • 1 … 10 mV sensitivity
    • Standard installation housing with 96 x 48 mm and protection class IP65
    • Bright and high-contrast graphic display with event-dependent color variants
    • Emulation of a 7-segment display with symbols and units
    • Intuitive and simple parameterization through plain text and touchscreen
    • Numerous functions such as tare, filter, averaging
    • Linearization with 24 support points

    Options

    • Option AC: Power supply 115 ... 230 VAC
    • Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
    • Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
    • Option CO: 4 control outputs, serial RS232 interface
    • Option CR: 4 control outputs, serial RS485 interface
    • Option RL: 2 relay outputs
    • Option IO: IO-Link Device V1.1
    Options can be combined.
  • Features

    • 4 independent input channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422], also possible for single-channel
    • 4 output channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422]
    • Maximum input frequency 1 MHz
    • Very short conversion time < 300 ns
    • Optical wavelength 1300 nm
    • Transmission distance up to 3000 meters
    • Power supply 5 VDC (for LW213)
    • Power supply 10 ... 30 VDC (for LW213-1, LW213-2, LW213-3)
    • Snap-on housing for top-hat rail (according to EN 60715)
    • Pre-configured optical fibres are available
  • Features

    • 4 independent input channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422], also possible for single channel
    • 4 output channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422]
    • Maximum input frequency 1 MHz
    • Very short conversion time < 300 ns
    • Optical wavelength 1300 nm
    • Transmission distances up to 3000 meters
    • Power supply 5 VDC (for LW214)
    • Power supply 10 ... 30 VDC (for LW214-1, LW214-2)
    • Snap-on housing for top-hat rail (according to EN 60715)
    • Pre-configured optical fibers are available
  • Features

    • 4 independent input channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422], also possible for single channel
    • 4 output channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422]
    • Maximum input frequency 1 MHz
    • Very short conversion time < 300 ns
    • Optical wavelength 850 nm
    • Transmission distance up to 2000 meters
    • Power supply 5 VDC (for LW215)
    • Power supply 10 ... 30 VDC (for LW215-1, LW215-2, LW216-3)
    • Snap-on housing for top-hat rail (according to EN 60715)
    • Pre-configured optical fibers are available
  • Features

    • 4 independent input channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422], also possible for single channel
    • 4 output channels with format A, B, C, D [HTL] or A, /A, B, /B, C, /C, D, /D [RS422]
    • Maximum input frequency 1 MHz
    • Very short conversion time < 300 ns
    • Optical wavelength 850 nm
    • Transmission distance up to 2000 meters
    • Power supply 5 VDC (for LW216)
    • Power supply 10 ... 30 VDC (for LW216-1, LW216-2)
    • Snap-on housing for top-hat rail (according to EN 60715)
    • Pre-configured optical fibers are available
  • Features

    • 1 SSI input / output channel [RS422] with format DATA+, DATA-, CLOCK+, CLOCK-
    • 1 Error input (LW217) resp. 1 open-drain-output (LW218)
    • Maximum input frequency 1 MHz
    • Very short conversion time < 300 nsec.
    • Optical wavelength 850 nm
    • Transmission distance up to 2000 meters
    • Power supply 5 VDC (for LW217)
    • Power supply 10 ... 30 VDC (for LW217-1)
    • Free adjustable SSI resolution from 1 ... 99 bit
    • Snap-on housing for top-hat rail (according to EN 60715)
    • Pre-configured optical fibres are available
  • Features

    • 1 SSI input / output channel [RS422] with format DATA+, DATA-, CLOCK+, CLOCK-
    • 1 open-drain-output (LW218)
    • Maximum input frequency 1 MHz
    • Very short conversion time < 300 ns
    • Optical wavelength 1300 nm
    • Transmission distance up to 2000 meters
    • Power supply 5 VDC (for LW218)
    • Power supply 10 ... 30 VDC (for LW218-1)
    • Free adjustable SSI resolution from 1 ... 99 bit
    • Snap-on housing for top-hat rail (according to EN 60715)
    • Glass fibre cables are available ready-assembled
  • Features

    • 4 pulse inputs with format  A, /A, B, /B [RS422]
    • 4 scalable 12-bit analog inputs for ±10 V or 0/4 ... 20 mA
    • 8 control inputs for PNP signals [10 ... 30 VDC]
    • 4 scalable 12-bit analog outputs for ±10 V or 0/4 ... 20 mA
    • Short loop time (depending on application)
    • Power supply 18 ... 35 VDC
    • Snap-on housing for top-hat rail (according to EN 60715)
    • Setup via Windows operator software (free of charge)
    • OnBoard interfaces: RS232 and CANopen