• Features

    • Scalable 14-bit analog input for 0 ... 10 V or 0/4 ... 20 mA
    • Power supply 24 VDC
    • Miniature norm panel housing
    • 5 digits LED display with 8 mm height
    • Display range -19999 ... 99999, adjustable zero and full-scale value
    • Latch input to freeze the display, minimum/maximum record memory
    • Easy to set up with only two front keys and menu support
    • Delivery includes adapter frame for 50 x 25 mm cut out and label set with dimensions
    • Front dimension 48 x 24 x 59 mm (1.89 x 0.945 x 2.322")
  • Features

    • 2 universal 16-bit analog inputs for ±10 V or 0/4 … 20 mA
    • 3 control inputs for HTL / PNP signals
    • Power supply 18 ... 30 VDC
    • 24 V auxiliary output for encoder supply
    • High accuracy reference output 10 V for potentiometers > 1 kOhm
    • 3.78 x 1.89-inch norm panel housing and IP65 protection
    • Bright and high-contrast display with event-dependent color variations
    • Emulation of a 7-segment display inclusively icons and units
    • Intuitive and easy parameterization by plain text and touchscreen
    • Operating modes for visualization of INPUT 1, INPUT 2 or combinations of IN1 + IN2, IN1 - IN2, IN1 x IN2, IN1: IN2
    • Numerous features, e. g. Ttara, filters, averaging
    • Linearization with 24 control points

    Option IO (= IO-Link Device)

    • Data transfer via COM3 (230,4 kBaud)
    • Cycle times < 3 msec
    • Process data IN 32 Byte (6 x process values from AX350): - Analog value 1 (scaled / linearized) and unit - Analog value 2 (scaled / linearized) and unit - Analog value 1 (scaled / linearized) with totalisation and unit - Analog value 2 (scaled / linearized) with totalisation and unit - Shortcut analogue value 1 (scaled / linearized) with analogue value 2  (scaled / linearized) and unit - Shortcut totalisator analogue value 1 (scaled / linearized) with totalisator analogue value 2 (scaled / linearized) and unit
    • Process data Out 8 Byte (2 x IO-Link process values to AX350): - IOL process value Out 1 with scaling, adjustable decimal point and programmable units - IOL process values Out 2 with scaling, adjustable decimal point and programmable units

    Combinable with further options:

    • Option AC: Power supply 115 ... 230 VAC
    • Option AO: 16-bit analog output, 4 control outputs, serial RS232 interface
    • Option AR: 16-bit analog output, 4 control outputs, serial RS485 interface
    • Option CO: 4 control outputs, serial RS232 interface
    • Option CR: 4 control outputs, serial RS485 interface
    • Option RL: 2 relay outputs
  • Features

    • 2 pulse inputs with format A, B, 90° [HTL] or A, /A, B, /B [RS422]
    • 4 control inputs for HTL / PNP / NPN / Namur signals [10 ... 30 VDC]
    • Input frequency up to 300 kHz
    • 4 fast transistor outputs, push-pull, short-circuit-proof [5 … 30 VDC]
    • 1 scalable 14-bit analog output (±10 V or 0/4 … 20 mA)
    • Loop time approx. 250 µs
    • Power supply 24 VAC and 17 … 40 VDC
    • Compact norm panel housing (according to EN 60715)
    • Top hat rail mounting by using SM300 support brackets (option)
    • Setup via keys or via PC by serial RS232 interface
    • PROFIBUS connection via Motrona gateway PB251
  • Features

    • 2 pulse inputs with format A, B, 90° [HTL] or A, /A, B, /B [RS422]
    • 4 control inputs for HTL / PNP / NPN / Namur signals [10 ... 30 VDC]
    • Input frequency up to 300 kHz
    • 4 fast transistor outputs, push-pull, short-circuit-proof [5 … 30 VDC]
    • 4 potential-free changeover relay outputs
    • 1 scalable 14-bit analog output (±10 V or 0/4 … 20 mA)
    • Loop time approx. 250 µs
    • Power supply 24 VAC and 17 … 40 VDC
    • Compact norm panel housing (according to EN 60715)
    • Top hat rail mounting by using SM600 support brackets (option)
    • Setup via keys or via PC by serial RS232 interface
    • PROFIBUS connection via Motrona gateway PB251
  • Features

    • MC700 is a universal motion controller for 1 to 4 axes, which can be assigned any motion control functions by loading firmware. Together with the firmware BY701 (see firmware), this controller offers excellent synchronous functions for 1 - 4 axes.
    • The firmware offers all conceivable possibilities for the synchronization of drives, including the influence of phase position and the relative position between the drives and numerous index and print mark functions.
    • Optionally, a "physical master" or the built-in "virtual master axis" with programmable speeds and ramps can be used as the master drive.
    • The number of successive axes can be extended arbitrarily via a cascading output.
    • MC700 controllers can be operated via an external control terminal, serial interface or optional via CANBUS (MC700/CI). PC operator software is included.
    • PROFIBUS connection possible via gateway PB251 (see accessories)
  • Features

    • 2 pulse inputs with format A, B, 90° [HTL] or A, /A, B, /B [RS422]
    • 4 control inputs for HTL / PNP / NPN / Namur signals [10 ... 30 VDC]
    • Input frequency up to 300 kHz
    • 4 fast transistor outputs, push-pull, short-circuit-proof [5 … 30 VDC]
    • 1 scalable 14-bit analog output (±10 V or 0/4 … 20 mA)
    • Loop time approx. 250 µs
    • Cutting length specification via keyboard
    • Power supply 24 VAC and 17 … 40 VDC
    • Compact norm panel housing (according to EN 60715)
    • Top hat rail mounting by using SM300 support brackets (option)
    • Setup via keys or via PC by serial RS232 interface
    • PROFIBUS connection via Motrona gateway PB251
  • Features

    • 2 pulse inputs with format A, B, 90° [HTL] or A, /A, B, /B [RS422]
    • 4 control inputs for HTL / PNP / NPN / Namur signals [10 ... 30 VDC]
    • Input frequency up to 300 kHz
    • 4 fast transistor outputs, push-pull, short-circuit-proof [5 … 30 VDC]
    • 4 potential-free changeover relay outputs
    • 1 scalable 14-bit analog output (±10 V or 0/4 … 20 mA)
    • Loop time approx. 250 µs
    • Cutting length specification via BCD decade switch on the front
    • Power supply 24 VAC and 17 … 40 VDC
    • Compact norm panel housing (according to EN 60715)
    • Top hat rail mounting by using SM600 support brackets (option)
    • Setup via keys or via PC by serial RS232 interface
    • PROFIBUS connection via Motrona gateway PB251
  • Features

    • 6-wire connection for one strain gauge full bridge sensor
    • 4 control inputs [HTL/PNP]
    • 1 analog output ±10 V, 0/4 ... 20 mA, 16 bit
    • 4 control outputs for signalling different operation states
    • Power supply 18 ... 30 VDC
    • Functions for scaling and linking the sensor signals (e.g. A+B, A-B, ...)
    • Adjustable bridge voltage per sensor from 3 VDC ... 10 VDC
    • Sensitivity of the sensor inputs 1 ... 10 mV
    • Transmission of the sensor data via RS485
    • Programming via USB and the user interface OS (freeware)
    • Protection class IP20
    • Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)
  • Features

    • 6-wire connection for two independent strain gauge full bridge sensors
    • 4 control inputs [HTL/PNP]
    • 2 independent analog outputs ±10 V, 0/4 ... 20 mA, 16 bit
    • 4 control outputs for signalling different operation states
    • Power supply 18 ... 30 VDC
    • Functions for scaling and linking the sensor signals (e.g. A+B, A-B, ...)
    • Adjustable bridge voltage per sensor from 3 VDC ... 10 VDC
    • Sensitivity of the sensor inputs 1 ... 10 mV
    • Transmission of the sensor data via RS485
    • Programming via USB and the user interface OS (freeware)
    • Protection class IP20
    • Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)
  • Features

    • Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
    • 4 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
    • BUS interface for quick and easy connection of the modules
    • Power supply 10 ... 30 VDC
    • Signal delay time 160 ns
    • Input level at RS422 / TTL (differential voltage > 0.5 V),
    • Input level at HTL differential (differential voltage > 2 V),
    • Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
    • Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
    • Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
    • Dimensions W x H x D = 34 x 118 x 140 mm (1,34 x 4,65 x 5,51")
  • Features

    • Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
    • 8 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
    • BUS interface for quick and easy connection of the modules
    • Power supply 10 ... 30 VDC
    • Signal delay time 160 ns
    • Input level at RS422 / TTL (differential voltage > 0.5 V),
    • Input level at HTL differential (differential voltage > 2 V),
    • Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
    • Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
    • Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
    • Dimensions W x H x D = 54 x 118 x 140 mm (2,13 x 4,65 x 5,51")
  • Features

    • Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
    • 4 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
    • BUS interface for quick and easy connection of the modules
    • Power supply 10 ... 30 VDC
    • Signal delay time 160 ns
    • Input level at RS422 / TTL (differential voltage > 0.5 V),
    • Input level at HTL differential (differential voltage > 2 V),
    • Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
    • Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
    • Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
    • Dimensions W x H x D = 34 x 118 x 140 mm (1,34 x 4,65 x 5,51")
  • Features

    • Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
    • 8 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
    • BUS interface for quick and easy connection of the modules
    • Power supply 10 ... 30 VDC
    • Signal delay time 160 ns
    • Input level at RS422 / TTL (differential voltage > 0.5 V),
    • Input level at HTL differential (differential voltage > 2 V),
    • Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
    • Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
    • Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
    • Dimensions W x H x D = 54 x 118 x 140 mm (2,13 x 4,65 x 5,51")
  • Features

    • Pulse input with format A, B, Z [HTL single-ended, TTL single-ended] or A, /A, B, /B, Z, /Z [RS422, HTL differential]
    • 4 control inputs for HTL, PNP signals [10 ... 30 VDC]
    • Input and output frequency up to 1 MHz
    • 3 incremental outputs with format A, /A, B, /B, Z, /Z, Push-Pull, [8 … 29 VDC]
    • Power supply 9 ... 30 VDC
    • Snap-on housing for top-hat rail (acc. EN 60715)
    • Multiplier/divisor adjustable as quotient F1 / F2
    • Multiplication/division without cumulative residual errors
    • Additional functions such as jog, trim, offset and reference
  • Features

    • Pulse input with format A, B, 90° [HTL] or A, /A, B, /B, Z, /Z [RS422]
    • 4 control inputs for PNP signals [10 ... 30 VDC]
    • Input and output frequency up to 1 MHz
    • Pulse output with format A, /A, B, /B, Z, /Z and push-pull characteristic, [5 ... 30 VDC]
    • Power supply 11 ... 30 VDC
    • Snap-on housing for top-hat rail (according to EN 60715)
    • LCD backlighted
    • Setup via keys, RS232
    • The device multiplies an incoming frequency by a proportional factor F1 and a reciprocal factor F2. The two factors F1 and F2 are adjustable in the range of 0.0005 to 9.9999
    • All operation modes provide error-free frequency conversion, with full consideration of the A / B phase and direction of the quadrature signals, therefore no cumulative errors, even with continuous changes of directions and vibrations
    • Zero pulse generator: the frequency multiplier generates at the output an index signal with an adjustable pulse interval, which can be synchronized as needed with the zero pulse at the input
  • Features

    • Frequency inputs A, B [HTL], A, / A, B, / B [RS422, HTL]
    • 3 control inputs (hold) for PNP signals [10 ... 30 VDC]
    • SSI input in the format DATA +, DATA-, CLOCK +, CLOCK- up to 32 bits
    • Start-stop interface for absolute transducers and magnetostrictive sensors
    • Input frequency up to 1 MHz
    • 25-bit parallel output push-pull in BCD, binary or Gray code format
    • Power supply 18 ... 30 VDC
    • Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)
  • Features

    • 2 pulse inputs with format A, B, 90° [HTL] or A, /A, B, /B [RS422]
    • 4 control inputs for HTL / PNP / NPN / Namur signals [10 ... 30 VDC]
    • Input frequency up to 300 kHz
    • 4 fast transistor outputs, push-pull, short-circuit-proof [5 … 30 VDC]
    • 1 scalable 14-bit analog output (±10 V or 0/4 … 20 mA)
    • Cutting length specification via keyboard
    • Power supply 24 VAC and 17 … 40 VDC
    • Compact norm panel housing (according to EN 60715)
    • Top hat rail mounting by using SM300 support brackets (option)
    • Setup via keys or via PC by serial RS232 interface
    • PROFIBUS connection via Motrona gateway PB251
  • Features

    • 2 pulse inputs with format A, B, 90° [HTL] or A, /A, B, /B [RS422]
    • 4 control inputs for HTL / PNP / NPN / Namur signals [10 ... 30 VDC]
    • Input frequency up to 300 kHz
    • 4 fast transistor outputs, push-pull, short-circuit-proof [5 … 30 VDC]
    • 4 potential-free changeover relay outputs
    • 1 scalable 14-bit analog output (±10 V or 0/4 … 20 mA)
    • Cutting length specification via keyboard or front BCD decade switch
    • Power supply 24 VAC and 17 … 40 VDC
    • Compact norm panel housing (according to EN 60715)
    • Top hat rail mounting by using SM600 support brackets (option)
    • Setup via keys or via PC by serial RS232 interface
    • PROFIBUS connection via Motrona gateway PB251
  • Features

    • Pulse inputs A, B [HTL], A, /A, B, /B [RS422, HTL]
    • Input frequency up to 1 MHz [RS422], 200 kHz [HTL]
    • Analog output ±10 V or 0/4 ... 20 mA, 16 Bit
    • Power supply 18 ... 30 VDC
    • Snap-on housing for top-hat rail (according to EN 60715)
    • Setup via operator software OS6.0
    • Serial RS232- / RS485 interface
    • SSI input DATA+, DATA-, CLOCK+, CLOCK- [RS422], 32 Bit
    • Start-stop interface for absolute transducers and magnetostrictive sensors
    • USB interface and RS232/RS485 interface for configuration and serial readout
  • Features

    • Control input with format [HTL]
    • 2 SSI inputs with format [RS422]
    • Cutt-off frequency 100 kHz ... 1 MHz
    • 2 encoder inputs, short-circuit-proof
    • 1 SSI output with format [RS422]
    • Power supply 12 ... 30 V DC
    • Current consumption (unloaded) 50 mA
    • Encoder supply 2 x 125mA (Vin – 2 V) short-circuit-proof
    • Delay / Output / Input100 ns
    • Operation temperature : 0 ... 45 °C (32 ... 113 °F)
    • SSI pause time min. 25 ns
    • Switching time is synchronized automatically with the next SSI break
    • Cascadable for more SSI encoders
    • All connections via pluggable screw terminal block
    • Snap-on housing for top-hat rail (according to EN 60715)
    • LEDs for indication of the input pulses
    • Dimension W x H x D = 22,5 x 121 x 112 mm (8.86 x 47.64 x 44.09'')
    • Plastic housing incl. plug
  • Features

    • 2 x 6 control outputs für HTL / PNP signals
    • Pulse inputs with format A, /A, B, /B, Z, /Z [RS422]
    • Input frequency up to 1 MHz
    • 2 encoder outputs, short-circuit-proof [TTL / RS422]
    • Power supply 12 ... 30 VDC
    • Current consumption (unloaded) 30 mA
    • Encoder supply 5 ... 35 VDC (extern connect to +VAUX)
    • Operation temperature: 0 ... 60 °C (32 ... 140°F)
    • Latency time < 250ns
    • Channel switching  < 1 ms
    • Open plastic housing for top-hat rail (according to EN 60715)
    • LEDs for indication of the input pulses
  • Features

    • 1 pulse input with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422]
    • Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
    • 2 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
    • BUS interface for quick and easy expansion of the number of outputs
    • Power supply 10 ... 30 VDC
    • Signal delay time 160 ns
    • Input level at RS422 / TTL (differential voltage > 0.5 V),
    • Input level at HTL differential (differential voltage > 2 V),
    • Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
    • Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
    • Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
    • Dimensions W x H x D = 34 x 118 x 140 mm (1,34 x 4,65 x 5,51")
  • Features

    • 1 pulse input with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422]
    • Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
    • 4 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
    • BUS interface for quick and easy expansion of the number of outputs
    • Power supply 10 ... 30 VDC
    • Signal delay time 160 ns
    • Input level at RS422 / TTL (differential voltage > 0.5 V),
    • Input level at HTL differential (differential voltage > 2 V),
    • Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
    • Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
    • Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
    • Dimensions W x H x D = 34 x 118 x 140 mm (1,34 x 4,65 x 5,51")
  • Features

    • 1 pulse input with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422]
    • Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
    • 8 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
    • BUS interface for quick and easy expansion of the number of outputs
    • Power supply 10 ... 30 VDC
    • Signal delay time 160 ns
    • Input level at RS422 / TTL (differential voltage > 0.5 V),
    • Input level at HTL differential (differential voltage > 2 V),
    • Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
    • Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
    • Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
    • Dimensions W x H x D = 54 x 118 x 140 mm (2,13 x 4,65 x 5,51")
  • Features

    • 1 encoder input programmable with format A, /A, B, /B, Z, /Z [TTL / RS422] or optionally A, B, Z [HTL]
    • Input frequency 750 kHz [TTL] or 300 kHz [HTL]
    • 2 pulse outputs with format A, /A, B, /B, Z, /Z with individual adjustable output levels 5 V [TTL] or 10 ... 30 V [HTL]
    • Power supply optionally 5 VDC or 10 ... 30 VDC
    • Auxiliary voltage +5 V for encoder supply 10 ... 30 VDC

Title