• Features

    • Number of output pulses per revolution 18000-1800000 ppr
    • Line number on disc (z) 18000
    • Reference signal - standard: 1 per shaft revolution - distance coded: 36 per shaft revolution
    • Maximum shaft speed 5000 rpm
    • Maximum shaft load - radial: 10 N
    • Accuracy ± 7.5 arc. sec; ± 5.0 arc. sec
    • Starting torque at 20°C ≤ 0.01 Nm
    • Rotor moment of inertia < 20x10-6 kgm2
    • Protection (IEC 529) IP64
    • Maximum weight without cable 0.7 kg
    • Operating temperature 0...+50°C
    • Storage temperature -30...+80°C
    • Maximum humidity (non-condensing) 98%
    • Permissible vibration (55 to 2000 Hz) ≤ 100 m/s²
    • Permissible shock (11 ms) ≤ 300m/s²
  • Features

    • Number of output pulses per revolution 18000-1800000 ppr
    • Line number on disc (z) 18000; 36000
    • Reference signal - standard: 1 per shaft revolution - distance coded for z = 18000: 36 per shaft revolution - distance coded for z = 36000: 72 per shaft revolution
    • Permissible mech. speed ≤ 1000 rpm
    • Max. operating speed 300 to 500 rpm
    • Accuracy ± 2.5 arc. sec
    • Permissible shaft load - axial: ≤ 30 N - radial: ≤ 30 N
    • Starting torque at 20°C ≤ 0.012 Nm
    • Rotor moment of inertia < 3.7x10-4 kgm2
    • Protection (IEC 529) IP64
    • Maximum weight without cable 3.5 kg
    • Operating temperature 0...+70°C
    • Storage temperature -30...+85°C
    • Maximum humidity (non-condensing) 98%
    • Permissible vibration (55 to 2000 Hz) ≤ 100 m/s²
    • Permissible shock (11 ms) ≤ 300m/s²
  • Features

    • Number of output pulses per revolution 18000-1800000 ppr
    • Line number on disc (z) 18000; 36000
    • Reference signal - standard: 1 per shaft revolution - distance coded for z = 18000: 36 per shaft revolution - distance coded for z = 36000: 72 per shaft revolution
    • Permissible mech. speed ≤ 1000 rpm
    • Max. operating speed 300 to 500 rpm
    • Accuracy ± 2.5 arc. sec
    • Permissible shaft load - axial: 0.02 mm - radial: 0.02 mm
    • Starting torque at 20°C ≤ 0.012 Nm
    • Rotor moment of inertia < 3.7x10-4 kgm2
    • Protection (IEC 529) IP64
    • Maximum weight without cable 4.1 kg
    • Operating temperature 0...+70°C
    • Storage temperature -30...+85°C
    • Maximum humidity (non-condensing) 98%
    • Permissible vibration (55 to 2000 Hz) ≤ 100 m/s²
    • Permissible shock (11 ms) ≤ 300m/s²
  • Features

    • Number of output pulses per revolution 3.600.000
    • Line number on disc (z) 36000
    • Reference signal - 1 per shaft revolution - 36 per shaft revolution - 72 per shaft revolution
    • Permissible mech. speed ≤ 1000 rpm
    • Max. operating speed 300 to 500 rpm
    • Accuracy ± 2.0 arc. sec
    • Permissible shaft load - axial: 0.02 mm - radial: 0.02 mm
    • Starting torque at 20°C ≤ 0.5 Nm
    • Rotor moment of inertia < 0.9x10-3 kgm2
    • Protection (IEC 529) IP64
    • Maximum weight without cable 4.5 kg
    • Operating temperature 0...+70°C
    • Storage temperature -30...+85°C
    • Maximum humidity (non-condensing) 98%
    • Permissible vibration (55 to 2000 Hz) ≤ 100 m/s²
    • Permissible shock (11 ms) ≤ 300m/s²
  • Features

    • Number of output pulses per revolution 18000-1800000 ppr
    • Line number on disc (z) 18000
    • Reference signal - standard: 1 per shaft revolution - distance coded: 36 per shaft revolution
    • Permissible mech. speed ≤ 3000 rpm
    • Max. operating speed 600 to 1000 rpm
    • Accuracy grades ± 5.0 arc. sec
    • Permissible shaft runout - axial: 0.02 mm - radial: ± 0.02 mm
    • Starting torque at 20°C ≤ 0.08 Nm
    • Rotor moment of inertia < 0.6x10-4 kgm2
    • Protection (IEC 529) IP64
    • Maximum weight without cable 1.2 kg
    • Operating temperature 0...+70°C
    • Storage temperature -30...+85°C
    • Maximum humidity (non-condensing) 98%
    • Permissible vibration (55 to 2000 Hz) ≤ 100 m/s²
  • Features

    • Absolute measuring method
    • Hollow shaft diameter (up to 50 mm)
    • Integrated stator coupling
    • Simple installation

    Typical field of application

    • Rotational axes with reduced accuracy requirements
  • Features

    • Absolute measuring method
    • Large hollow shaft diameter (up to 100 mm)
    • Integrated stator coupling
    • Compact size for limited installation space
    • System accuracy includes the deviation caused by the shaft connection
    • Outstanding dynamic response
    • Simple installation

    Typical field of application

    • Rotary tables
    • Swivel heads
  • Features

    • Incremental measuring method
    • Solid shaft
    • Separate shaft coupling for large mounting tolerances
    • System accuracy does not include the deviation caused by the shaft connection

    Typical field of application

    • Rotational axes
  • Features

    • Incremental measuring method
    • Large hollow shaft diameter (up to 60 mm)
    • Integrated stator coupling
    • Compact size for limited installation space
    • System accuracy includes the deviation caused by the shaft connection
    • Outstanding dynamic response
    • Simple installation

    Typical field of application

    • Rotary tables
    • Swivel heads
  • Features

    • Large hollow shaft diameter (up to 10 m with a scale tape)
    • High shaft speeds up to 20,000 rpm
    • No additional starting torque from shaft seals
    • Segment versions
    • Also available with Functional Safety Modular angle encoders with optical scanning are available with various graduation carriers:
      • ERP/ERO: Glass circular scale with hub
      • ERA/ECA 4000: Steel drum
      • ERA 7000/8000: Steel scale tape

    Typical field of application

    • High-resolution rotary axes with high reproducibility
    • Very high number of signal periods
    • Small mounting space
    • Small interpolation error and low signal noise
  • Features

    • Internal power supply 3,3 V
    • Ambient temperature 0° C ... +60° C / 32° F ... 140° F (operating), -40° C ... +70° C / -40° F ... 158° F (storage)
    • 10, 20, 50, 100, 125, 250, 500, 800 und 1000 kbps Baud rates
    • SUB-D-9-pin male, galvanically isolated
  • Features

    • USB to RS232 converter (compatible with all existing Windows versions)
    • Serial RS232 cable (for connection between the converter and motrona unit)
    • One connector Sub-D-9 (male)
    • One connector Sub-D-9 (female)
    • Length 3 m (approx. 10 feet)
    • Windows driver CD enclosed
  • Features

    • Solder connection
    • Metallised plastic enclosure
    • Mounting screws included
  • Features

    • Solder connection
    • Metallised plastic enclosure
    • Mounting screws included
  • Features

    • 6-wire connection for one strain gauge full bridge sensor
    • 4 control inputs [HTL/PNP]
    • 1 analog output ±10 V, 0/4 ... 20 mA, 16 bit
    • 4 control outputs for signalling different operation states
    • Power supply 18 ... 30 VDC
    • Functions for scaling and linking the sensor signals (e.g. A+B, A-B, ...)
    • Adjustable bridge voltage per sensor from 3 VDC ... 10 VDC
    • Sensitivity of the sensor inputs 1 ... 10 mV
    • Transmission of the sensor data via RS485
    • Programming via USB and the user interface OS (freeware)
    • Protection class IP20
    • Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)
  • Features

    • 6-wire connection for two independent strain gauge full bridge sensors
    • 4 control inputs [HTL/PNP]
    • 2 independent analog outputs ±10 V, 0/4 ... 20 mA, 16 bit
    • 4 control outputs for signalling different operation states
    • Power supply 18 ... 30 VDC
    • Functions for scaling and linking the sensor signals (e.g. A+B, A-B, ...)
    • Adjustable bridge voltage per sensor from 3 VDC ... 10 VDC
    • Sensitivity of the sensor inputs 1 ... 10 mV
    • Transmission of the sensor data via RS485
    • Programming via USB and the user interface OS (freeware)
    • Protection class IP20
    • Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)
  • Features

    • Solder connection
    • Metallised plastic enclosure
    • Mounting screws included
  • Features

    • Solder connection
    • Metallised plastic enclosure
    • Mounting screws included
  • Features

    • Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
    • 4 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
    • BUS interface for quick and easy connection of the modules
    • Power supply 10 ... 30 VDC
    • Signal delay time 160 ns
    • Input level at RS422 / TTL (differential voltage > 0.5 V),
    • Input level at HTL differential (differential voltage > 2 V),
    • Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
    • Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
    • Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
    • Dimensions W x H x D = 34 x 118 x 140 mm (1,34 x 4,65 x 5,51")
  • Features

    • Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
    • 8 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
    • BUS interface for quick and easy connection of the modules
    • Power supply 10 ... 30 VDC
    • Signal delay time 160 ns
    • Input level at RS422 / TTL (differential voltage > 0.5 V),
    • Input level at HTL differential (differential voltage > 2 V),
    • Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
    • Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
    • Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
    • Dimensions W x H x D = 54 x 118 x 140 mm (2,13 x 4,65 x 5,51")
  • Features

    • Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
    • 4 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
    • BUS interface for quick and easy connection of the modules
    • Power supply 10 ... 30 VDC
    • Signal delay time 160 ns
    • Input level at RS422 / TTL (differential voltage > 0.5 V),
    • Input level at HTL differential (differential voltage > 2 V),
    • Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
    • Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
    • Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
    • Dimensions W x H x D = 34 x 118 x 140 mm (1,34 x 4,65 x 5,51")
  • Features

    • Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
    • 8 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
    • BUS interface for quick and easy connection of the modules
    • Power supply 10 ... 30 VDC
    • Signal delay time 160 ns
    • Input level at RS422 / TTL (differential voltage > 0.5 V),
    • Input level at HTL differential (differential voltage > 2 V),
    • Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
    • Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
    • Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
    • Dimensions W x H x D = 54 x 118 x 140 mm (2,13 x 4,65 x 5,51")
  • Features

    • Sub-D-9 connectors (male) on both sides
    • cable length 10 cm (approx. 3.4")
  • Features

    • Pulse input with format A, B, Z [HTL single-ended, TTL single-ended] or A, /A, B, /B, Z, /Z [RS422, HTL differential]
    • 4 control inputs for HTL, PNP signals [10 ... 30 VDC]
    • Input and output frequency up to 1 MHz
    • 3 incremental outputs with format A, /A, B, /B, Z, /Z, Push-Pull, [8 … 29 VDC]
    • Power supply 9 ... 30 VDC
    • Snap-on housing for top-hat rail (acc. EN 60715)
    • Multiplier/divisor adjustable as quotient F1 / F2
    • Multiplication/division without cumulative residual errors
    • Additional functions such as jog, trim, offset and reference
  • Features

    • Pulse input with format A, B, 90° [HTL] or A, /A, B, /B, Z, /Z [RS422]
    • 4 control inputs for PNP signals [10 ... 30 VDC]
    • Input and output frequency up to 1 MHz
    • Pulse output with format A, /A, B, /B, Z, /Z and push-pull characteristic, [5 ... 30 VDC]
    • Power supply 11 ... 30 VDC
    • Snap-on housing for top-hat rail (according to EN 60715)
    • LCD backlighted
    • Setup via keys, RS232
    • The device multiplies an incoming frequency by a proportional factor F1 and a reciprocal factor F2. The two factors F1 and F2 are adjustable in the range of 0.0005 to 9.9999
    • All operation modes provide error-free frequency conversion, with full consideration of the A / B phase and direction of the quadrature signals, therefore no cumulative errors, even with continuous changes of directions and vibrations
    • Zero pulse generator: the frequency multiplier generates at the output an index signal with an adjustable pulse interval, which can be synchronized as needed with the zero pulse at the input

Title

Go to Top