• Features

    • 2 pulse inputs with format A, B, 90° [HTL] or A, /A, B, /B [RS422]
    • 4 control inputs for HTL / PNP / NPN / Namur signals [10 ... 30 VDC]
    • Input frequency up to 300 kHz
    • 4 fast transistor outputs, push-pull, short-circuit-proof [5 … 30 VDC]
    • 1 scalable 14-bit analog output (±10 V or 0/4 … 20 mA)
    • Loop time approx. 250 µs
    • Power supply 24 VAC and 17 … 40 VDC
    • Compact norm panel housing (according to EN 60715)
    • Top hat rail mounting by using SM300 support brackets (option)
    • Setup via keys or via PC by serial RS232 interface
    • PROFIBUS connection via Motrona gateway PB251
  • Features

    • 2 pulse inputs with format A, B, 90° [HTL] or A, /A, B, /B [RS422]
    • 4 control inputs for HTL / PNP / NPN / Namur signals [10 ... 30 VDC]
    • Input frequency up to 300 kHz
    • 4 fast transistor outputs, push-pull, short-circuit-proof [5 … 30 VDC]
    • 4 potential-free changeover relay outputs
    • 1 scalable 14-bit analog output (±10 V or 0/4 … 20 mA)
    • Loop time approx. 250 µs
    • Power supply 24 VAC and 17 … 40 VDC
    • Compact norm panel housing (according to EN 60715)
    • Top hat rail mounting by using SM600 support brackets (option)
    • Setup via keys or via PC by serial RS232 interface
    • PROFIBUS connection via Motrona gateway PB251
  • Features

    • MC700 is a universal motion controller for 1 to 4 axes, which can be assigned any motion control functions by loading firmware. Together with the firmware BY701 (see firmware), this controller offers excellent synchronous functions for 1 - 4 axes.
    • The firmware offers all conceivable possibilities for the synchronization of drives, including the influence of phase position and the relative position between the drives and numerous index and print mark functions.
    • Optionally, a "physical master" or the built-in "virtual master axis" with programmable speeds and ramps can be used as the master drive.
    • The number of successive axes can be extended arbitrarily via a cascading output.
    • MC700 controllers can be operated via an external control terminal, serial interface or optional via CANBUS (MC700/CI). PC operator software is included.
    • PROFIBUS connection possible via gateway PB251 (see accessories)
  • Features

    • 2 pulse inputs with format A, B, 90° [HTL] or A, /A, B, /B [RS422]
    • 4 control inputs for HTL / PNP / NPN / Namur signals [10 ... 30 VDC]
    • Input frequency up to 300 kHz
    • 4 fast transistor outputs, push-pull, short-circuit-proof [5 … 30 VDC]
    • 1 scalable 14-bit analog output (±10 V or 0/4 … 20 mA)
    • Loop time approx. 250 µs
    • Cutting length specification via keyboard
    • Power supply 24 VAC and 17 … 40 VDC
    • Compact norm panel housing (according to EN 60715)
    • Top hat rail mounting by using SM300 support brackets (option)
    • Setup via keys or via PC by serial RS232 interface
    • PROFIBUS connection via Motrona gateway PB251
  • Features

    • 2 pulse inputs with format A, B, 90° [HTL] or A, /A, B, /B [RS422]
    • 4 control inputs for HTL / PNP / NPN / Namur signals [10 ... 30 VDC]
    • Input frequency up to 300 kHz
    • 4 fast transistor outputs, push-pull, short-circuit-proof [5 … 30 VDC]
    • 4 potential-free changeover relay outputs
    • 1 scalable 14-bit analog output (±10 V or 0/4 … 20 mA)
    • Loop time approx. 250 µs
    • Cutting length specification via BCD decade switch on the front
    • Power supply 24 VAC and 17 … 40 VDC
    • Compact norm panel housing (according to EN 60715)
    • Top hat rail mounting by using SM600 support brackets (option)
    • Setup via keys or via PC by serial RS232 interface
    • PROFIBUS connection via Motrona gateway PB251
  • Features

    • Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
    • 4 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
    • BUS interface for quick and easy connection of the modules
    • Power supply 10 ... 30 VDC
    • Signal delay time 160 ns
    • Input level at RS422 / TTL (differential voltage > 0.5 V),
    • Input level at HTL differential (differential voltage > 2 V),
    • Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
    • Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
    • Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
    • Dimensions W x H x D = 34 x 118 x 140 mm (1,34 x 4,65 x 5,51")
  • Features

    • Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
    • 8 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
    • BUS interface for quick and easy connection of the modules
    • Power supply 10 ... 30 VDC
    • Signal delay time 160 ns
    • Input level at RS422 / TTL (differential voltage > 0.5 V),
    • Input level at HTL differential (differential voltage > 2 V),
    • Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
    • Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
    • Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
    • Dimensions W x H x D = 54 x 118 x 140 mm (2,13 x 4,65 x 5,51")
  • Features

    • Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
    • 4 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
    • BUS interface for quick and easy connection of the modules
    • Power supply 10 ... 30 VDC
    • Signal delay time 160 ns
    • Input level at RS422 / TTL (differential voltage > 0.5 V),
    • Input level at HTL differential (differential voltage > 2 V),
    • Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
    • Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
    • Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
    • Dimensions W x H x D = 34 x 118 x 140 mm (1,34 x 4,65 x 5,51")
  • Features

    • Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
    • 8 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
    • BUS interface for quick and easy connection of the modules
    • Power supply 10 ... 30 VDC
    • Signal delay time 160 ns
    • Input level at RS422 / TTL (differential voltage > 0.5 V),
    • Input level at HTL differential (differential voltage > 2 V),
    • Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
    • Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
    • Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
    • Dimensions W x H x D = 54 x 118 x 140 mm (2,13 x 4,65 x 5,51")
  • Features

    • 2 pulse inputs with format A, B, 90° [HTL] or A, /A, B, /B [RS422]
    • 4 control inputs for HTL / PNP / NPN / Namur signals [10 ... 30 VDC]
    • Input frequency up to 300 kHz
    • 4 fast transistor outputs, push-pull, short-circuit-proof [5 … 30 VDC]
    • 1 scalable 14-bit analog output (±10 V or 0/4 … 20 mA)
    • Cutting length specification via keyboard
    • Power supply 24 VAC and 17 … 40 VDC
    • Compact norm panel housing (according to EN 60715)
    • Top hat rail mounting by using SM300 support brackets (option)
    • Setup via keys or via PC by serial RS232 interface
    • PROFIBUS connection via Motrona gateway PB251
  • Features

    • 2 pulse inputs with format A, B, 90° [HTL] or A, /A, B, /B [RS422]
    • 4 control inputs for HTL / PNP / NPN / Namur signals [10 ... 30 VDC]
    • Input frequency up to 300 kHz
    • 4 fast transistor outputs, push-pull, short-circuit-proof [5 … 30 VDC]
    • 4 potential-free changeover relay outputs
    • 1 scalable 14-bit analog output (±10 V or 0/4 … 20 mA)
    • Cutting length specification via keyboard or front BCD decade switch
    • Power supply 24 VAC and 17 … 40 VDC
    • Compact norm panel housing (according to EN 60715)
    • Top hat rail mounting by using SM600 support brackets (option)
    • Setup via keys or via PC by serial RS232 interface
    • PROFIBUS connection via Motrona gateway PB251
  • Features

    • 2 x 6 control outputs für HTL / PNP signals
    • Pulse inputs with format A, /A, B, /B, Z, /Z [RS422]
    • Input frequency up to 1 MHz
    • 2 encoder outputs, short-circuit-proof [TTL / RS422]
    • Power supply 12 ... 30 VDC
    • Current consumption (unloaded) 30 mA
    • Encoder supply 5 ... 35 VDC (extern connect to +VAUX)
    • Operation temperature: 0 ... 60 °C (32 ... 140°F)
    • Latency time < 250ns
    • Channel switching  < 1 ms
    • Open plastic housing for top-hat rail (according to EN 60715)
    • LEDs for indication of the input pulses
  • Features

    • 1 pulse input with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422]
    • Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
    • 2 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
    • BUS interface for quick and easy expansion of the number of outputs
    • Power supply 10 ... 30 VDC
    • Signal delay time 160 ns
    • Input level at RS422 / TTL (differential voltage > 0.5 V),
    • Input level at HTL differential (differential voltage > 2 V),
    • Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
    • Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
    • Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
    • Dimensions W x H x D = 34 x 118 x 140 mm (1,34 x 4,65 x 5,51")
  • Features

    • 1 pulse input with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422]
    • Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
    • 4 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
    • BUS interface for quick and easy expansion of the number of outputs
    • Power supply 10 ... 30 VDC
    • Signal delay time 160 ns
    • Input level at RS422 / TTL (differential voltage > 0.5 V),
    • Input level at HTL differential (differential voltage > 2 V),
    • Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
    • Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
    • Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
    • Dimensions W x H x D = 34 x 118 x 140 mm (1,34 x 4,65 x 5,51")
  • Features

    • 1 pulse input with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422]
    • Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
    • 8 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
    • BUS interface for quick and easy expansion of the number of outputs
    • Power supply 10 ... 30 VDC
    • Signal delay time 160 ns
    • Input level at RS422 / TTL (differential voltage > 0.5 V),
    • Input level at HTL differential (differential voltage > 2 V),
    • Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
    • Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
    • Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
    • Dimensions W x H x D = 54 x 118 x 140 mm (2,13 x 4,65 x 5,51")
  • Features

    • 1 pulse input with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422]
    • Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
    • 8 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
    • BUS interface for quick and easy expansion of the number of outputs
    • Power supply 10 ... 30 VDC
    • Signal delay time 160 ns
    • Input level at RS422 / TTL (differential voltage > 0.5 V),
    • Input level at HTL differential (differential voltage > 2 V),
    • Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
    • Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
    • Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
    • Dimensions W x H x D = 54 x 118 x 140 mm (2,13 x 4,65 x 5,51")
  • Features

    • 1 encoder input programmable with format A, /A, B, /B, Z, /Z [TTL / RS422] or optionally A, B, Z [HTL]
    • Input frequency 750 kHz [TTL] or 300 kHz [HTL]
    • 2 pulse outputs with format A, /A, B, /B, Z, /Z with individual adjustable output levels 5 V [TTL] or 10 ... 30 V [HTL]
    • Power supply optionally 5 VDC or 10 ... 30 VDC
    • Auxiliary voltage +5 V for encoder supply 10 ... 30 VDC
  • Features

    • 2 pulse inputs with format  A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422]
    • Input frequency up to 250 kHz for asymmetrical and up to 1 MHz for symmetric signals
    • 2 control inputs for HTL / PNP signals [10 ... 30 VDC]
    • 2 output channels with format  A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422], each output adjustable separately
    • Power supply 12 ... 30 VDC
    • Snap-on housing for top-hat rail (according to EN 60715)
  • Features

    • 1 pulse input with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422]
    • Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
    • 4 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
    • BUS interface for quick and easy expansion of the number of outputs
    • Power supply 10 ... 30 VDC
    • Signal delay time 160 ns
    • Input level at RS422 / TTL (differential voltage > 0.5 V),
    • Input level at HTL differential (differential voltage > 2 V),
    • Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
    • Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
    • Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
    • Dimensions W x H x D = 34 x 118 x 140 mm (1,34 x 4,65 x 5,51")
  • Features

    • 1 pulse input with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422]
    • Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
    • 8 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
    • BUS interface for quick and easy expansion of the number of outputs
    • Power supply 10 ... 30 VDC
    • Signal delay time 160 ns
    • Input level at RS422 / TTL (differential voltage > 0.5 V),
    • Input level at HTL differential (differential voltage > 2 V),
    • Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
    • Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
    • Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
    • Dimensions W x H x D = 54 x 118 x 140 mm (2,13 x 4,65 x 5,51")
  • Features

    • 1 pulse input with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422]
    • Input frequency up to 500 kHz with HTL or 1 MHz with RS422 / TTL
    • 8 pulse outputs, formats correspond to those of the input signals, but with individual assignment of the output level for each output
    • BUS interface for quick and easy expansion of the number of outputs
    • Power supply 10 ... 30 VDC
    • Signal delay time 160 ns
    • Input level at RS422 / TTL (differential voltage > 0.5 V),
    • Input level at HTL differential (differential voltage > 2 V),
    • Input level at HTL asymmetric low: 0 ... 6 V, high: 8 ... 40 V
    • Input level at TTL (asymmetrical): LOW < 0.8 V, HIGH >2.0 V
    • Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
    • Dimensions W x H x D = 54 x 118 x 140 mm (2,13 x 4,65 x 5,51")
  • Features

    • 4 pulse inputs with format  A, /A, B, /B [RS422]
    • 4 scalable 12-bit analog inputs for ±10 V or 0/4 ... 20 mA
    • 8 control inputs for PNP signals [10 ... 30 VDC]
    • 4 scalable 12-bit analog outputs for ±10 V or 0/4 ... 20 mA
    • Short loop time (depending on application)
    • Power supply 18 ... 35 VDC
    • Snap-on housing for top-hat rail (according to EN 60715)
    • Setup via Windows operator software (free of charge)
    • OnBoard interfaces: RS232 and CANopen
  • Features

    • The MC800 hardware is a universal motion controller, which serves for sophisticated control tasks in today’s machine engineering and drive technology. This motion controller can cover a wide application range due to the function features and settings of the equipped control firmware.
    • Typical control applications are e.g. drive synchronization of a master and slave axis, index and print mark evaluation, rotating cross cutters, flying and eccentric shears, label printing machines and many more.
    • The unique feature of the MC800 is the integrated tandem drive controller. This enables to reach the acceleration requirements of heavy loads by splitting the necessary power to two independent drives.
    • Further features are the flexible and combinable input configuration for different types of encoders, measuring systems and sensors, the high frequency range up to 2 MHz and the adaptive interface architecture.
    • Due to an extremely short position loop time of 250 µs, a self-optimizing polynomial motion profile, and excellent accuracy - even at high line speeds, the MC800 ensures a very smooth motion with maximum protection of the mechanical parts.
  • Features

    • 2 pulse inputs with format A, B, 90° [HTL] or A, /A, B, /B [RS422]
    • 4 control inputs for HTL / PNP / NPN / Namur signals [10 ... 30 VDC]
    • Input frequency up to 300 kHz
    • 4 fast transistor outputs, push-pull, short-circuit-proof [5 … 30 VDC]
    • 1 scalable 14-bit analog output (±10 V or 0/4 … 20 mA)
    • Loop time approx. 250 µs
    • Defining incremental dimensions via keyboard
    • Power supply 24 VAC and 17 … 40 VDC
    • Compact norm panel housing (according to EN 60715)
    • Top hat rail mounting by using SM300 support brackets (option)
    • Setup via keys or via PC by serial RS232 interface
    • PROFIBUS connection via mMotrona gateway PB251
  • Features

    • 2 pulse inputs with format A, B, 90° [HTL] or A, /A, B, /B [RS422]
    • 4 control inputs for HTL / PNP / NPN / Namur signals [10 ... 30 VDC]
    • Input frequency up to 300 kHz
    • 4 fast transistor outputs, push-pull, short-circuit-proof [5 … 30 VDC]
    • 1 scalable 14-bit analog output (±10 V or 0/4 … 20 mA)
    • Loop time approx. 250 µs
    • Defining incremental dimensions via keyboard or BCD decade switch on the front
    • Power supply 24 VAC and 17 … 40 VDC
    • Compact norm panel housing (according to EN 60715)
    • Top hat rail mounting by using SM600 support brackets (option)
    • Setup via keys or via PC by serial RS232 interface
    • PROFIBUS connection via Motrona gateway PB251
    • Dimension 96 x 96 x 140 mm (3,78 x 3,78 x 5,51")